Closed Solicitation · DEPT OF DEFENSE

    AC3 OPTIMUS INTRA-AORTIC PUMP

    Sol. F3G4BAPUMPSpecial NoticeNELLIS AFB, NV
    Closed
    STATUS
    Closed
    closed Aug 29, 2025
    POSTED
    Aug 26, 2025
    Publication date
    NAICS CODE
    334510
    Primary industry classification
    PSC CODE
    6515
    Product & service classification

    AI Summary

    The 99th Contracting Squadron plans to award a sole source Purchase Order to Marathon Medical for four AC3 Optimus Intra-Aortic Balloon Pump Systems with FiberOptix capability, citing unique qualifications and proprietary technology. Interested parties may submit capability statements, not exceeding five pages, demonstrating their ability to meet the requirement. This notice is not a request for competitive proposals, and the Government will decide whether to proceed with a competitive procurement based on the responses received.

    Contract details

    Solicitation No.
    F3G4BAPUMP
    Notice Type
    Special Notice
    Posted Date
    August 26, 2025
    Response Deadline
    August 29, 2025
    NAICS Code
    334510AI guide
    PSC / Class Code
    6515
    Issuing Office
    FA4861 99 CONS LGC
    Primary Contact
    Stephen Colton
    State
    NV
    ZIP Code
    89191-7063

    Description

    The 99th Contracting Squadron intends to award a sole source Purchase Order to Marathon Medical, located at 3251 Lewiston Street, Suite 16, Auora, CO 80011,under FAR Part 13.5 Simplified Procedures for Certain Commercial Products and Commercial Services and in conjunction with the following authorities: 10 U.S.C. 3204(a)(1), Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements: 10 U.S.C. 3204(a)(5), Authorized or Required by Statute and 41 U.S.C. 1901, Simplified Acquisition procedures.  The 99MDG Mike O’ Callagham Military Medical Center requires the following: 4ea – AC3 Optimus Intra- Aortic Balloon Pump System FiberOptix Capability. Marathon Medical is the only SDVOSB distributor who can provide this required equipment.

    This notice of intent is not a request for competitive proposals and no solicitation document exists for the requirement.. Sources interested in responding to this notice are required to submit a capability statement that includes technical data and cost information, in sufficient detail and with convincing evidence that clearly demonstrates the capability to meet the requirement. Capability statements shall not exceed 5 (8.5 x 11 inch) pages using a font size no smaller than 10-point.  All capability statements received by the closing date of this notice will be considered by the Government. A request for documentation or additional information or submissions that only ask questions will not be considered as an affirmative response.  A determination by the Government not to compete based on responses to this notice is solely within the discretion of the Government.  Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement or to proceed with a sole source purchase order.

    The following is a statement of the contractor’s unique qualifications and why the nature of this acquisition requires the use of the authorities cited above:

    Arrow® AC3 Optimus™ is the newest solution on the market; manufactured by Teleflex. Due to the proprietary nature of the real-time WAVE® Algorithm, no other brand of equipmentcan provides the required IABP. The main feature of this product is the Pro Active Counter Pulsation system enabling 98% inflation timing accuracy during IABP therapy, even when patients have severe arrhythmias. This provides the unique ability of the AutoCAT2 WAVE® system with FiberOptix® catheter technology to proactively anticipate individual arterial pressure closures before they occur, and provide accurate inflation timing, as well as triggering even during severe arrhythmias. The FiberOptix® catheter captures and transmits the high-fidelity arterial pressure signal at the speed of light, overcoming the delays seen with traditional fluid-filled arterial pressure (AP) signal systems. The proprietary real-time WAVE® Algorithm is the brain of the pump-it calculates aortic flow based on the AP signal for each beat (using real-time data). This enables it to capture every single heartbeat and then signal the pump to inflate. In heart failure cases, precisely timed IABP is critical for generating beat-to-beat improvements in systolic and diastolic left ventricular performance. No failure of Teleflex balloon has been reported, over its lifetime. This is important because a mechanical failure of the balloon requires immediate removal, which can lead to serious complications caused by micro clots that form on the balloon surface, e.g.: a) peripheral thrombosis, b) myocardial ischemia, c) hemodynamic decompensation, and d) late pseudoaneurysm.

    Marathon Medical is the only SDVOSB distributor who can provide this required equipment.

    Responses are due by 4:00 PM Pacific Daylight Time, 29 August 2025. Responses shall be submitted by email ONLY as a Microsoft Word or Adobe PDF attachment to the following address(es): stephen.colton@us.af.mil.

    Key dates

    1. August 26, 2025Posted Date
    2. August 29, 2025Proposals / Responses Due

    Frequently asked questions

    AC3 OPTIMUS INTRA-AORTIC PUMP is a federal acquisition solicitation issued by DEPT OF DEFENSE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.