Closed Solicitation · DEPT OF DEFENSE

    BIRCH LAKE WELL REPAIR

    Sol. FA500425Q0050Combined Synopsis/SolicitationSet-aside: Total Small Business Set-Aside (FAR 19.5)EIELSON AFB, AK
    Closed
    STATUS
    Closed
    closed Aug 12, 2025
    POSTED
    Aug 8, 2025
    Publication date
    NAICS CODE
    221310
    Primary industry classification
    PSC CODE
    S114
    Product & service classification

    AI Summary

    Eielson AFB requires well pump replacement and system repair at Birch Lake Recreational Facility in Alaska. Interested bidders should refer to the attached Combo Synopsis/Solicitation for detailed quote requirements. Quotes are due by August 11, 2025, at 4:30 AST. For inquiries, contact ashton.holland.1@us.af.mil.

    Contract details

    Solicitation No.
    FA500425Q0050
    Notice Type
    Combined Synopsis/Solicitation
    Set-Aside
    Total Small Business Set-Aside (FAR 19.5)
    Posted Date
    August 8, 2025
    Response Deadline
    August 12, 2025
    NAICS Code
    221310AI guide
    PSC / Class Code
    S114
    Issuing Office
    FA5004 354 CONS PK
    Primary Contact
    Ashton Holland
    State
    AK
    ZIP Code
    99702-2200
    AI Product/Service
    service

    Description

    Eielson AFB has a requirement for well pump replacement and system repair at our Birch Lake Recreational Facility located near North Pole, Alaska.

    Please use the attached Combo Synopsis/Solicitation information for details for quote requirements and submission instructions.

    All quotes are due August 11, 2025 at 4:30 AST.

    Please submit any questions you have to my email: ashton.holland.1@us.af.mil.
     

    The following are questions and answers that have been submitted.

    Does this well pump provide system pressure, or fill a water tank ?

    -              Pump provides water to fill storage tanks that have their own distribution pump to provide pressure to the site.

    What material is the pipe made of?

    -              Primarily all black iron and/or galvanized

    What is the size of the pipe?

    -              1-1/4”

    Is the pipe above ground or below ground?

    -              The casing and piping to be replaced is below ground (subsurface) and the connection to the rest of the line is above ground. The casing is accessible inside of a facility and the roof has a hatch to allow for crane operation. There is no pitless adapter for this well system.

    Does the electrical need to be above ground or below ground?

    -              The electrical for the control panel will be above ground and the cabling for the well pump will technically be below ground but within the casing. The only requirement would be for it to be watertight.

    Key dates

    1. August 8, 2025Posted Date
    2. August 12, 2025Proposals / Responses Due

    AI search tags

    Frequently asked questions

    BIRCH LAKE WELL REPAIR is a federal acquisition solicitation issued by DEPT OF DEFENSE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.