Closed Solicitation · DEPARTMENT OF HOMELAND SECURITY
AI Summary
The U.S. Coast Guard requires a contractor for fire suppression system testing on the USCGC Sturgeon Bay. The contractor must provide parts, conduct inspections, and ensure the system operates correctly. This opportunity is a combined synopsis/solicitation under RFQ 70Z08526Q0000855, set aside for small businesses, with a response deadline of December 29, 2025.
This is a combined synopsis/solicitation This is a combined synopsis/solicitation for commercial items/services prepared in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. Request for Quotations number is 70Z08526Q0000855 and is issued as a request for quotations (RFQ). This announcement constitutes the only solicitation; quotations are being requested, and a written solicitation will not be issued. This Request for Quotations incorporates provisions and clauses in effect through Federal Acquisition Circular 2005-65 dated January 29, 2013. The NAICS Code is 336611. The small business size standard is 1250. This is a totally small business set aside. All responsible sources may submit proposals that will be considered by the agency. The contract will be awarded on a firm-fixed-price basis using simplified acquisition procedures in accordance with FAR Part 13.5. All responses from interested vendors must be received on/before 0800 Pacific Time, December 29th, 2025, and will be reviewed by the Government. The United States Coast Guard Surface Force Logistics Center has a requirement for the following: Contractor shall provide parts requested for USCGC STURGEON BAY Fire Suppression System Testing: STATEMENT OF WORK CGC STURGEON BAY OPFAC: 17509 LOCATION: Bayonne, NJ EQUIPMENT: Hi-Fog Water Mist Fire Suppression System COMPONENT AFFECTED: 5yr and ANNUAL INSPECTION OF SYSTEM/ Renewal of 29 Bottles and certified MPC: R-A-13380, R-M-13373, R-C-14526 Contractor must be HI-FOG certified Technician. Contractor must set up water mist system for testing; complete the water mist system test; and place water mist system back in normal operation once test is completed. Contractor must ensure all connections, fittings, and equipment within the water mist system are operating correctly as well. Contractor shall use MPC R-A-13380, R-M-13373, R-C-14526 as guidance. Replacement Parts to be included in 5-Year Annual Inspection 1 - PNEUMATIC REPAIR KIT WITH SILENCER (G40090) 1 - HYDRAULICREPAIR KIT (G40095) 30 - HOSE 36INCH 8MM FOR GPU (UU1168) 1 - HOSE ASSEMBLY - N2 REGULATOR (A20079.1) 2 - FILTER WATERFILTER R1 1/2, 60-MICROMETER (E31048) 1 - LOW PRESSURE FRESH WATER SAFETY VALVES (M-0010165) 2 - SVM20 DNV VALVEREBUILD KITS (V14020) Any discrepancies found shall be noted; and corrected only if no other cost is needed. If any discrepancy causes cost outside the quote, this shall be routed through customer before discrepancy is corrected. POP: 22DEC2025-29DEC2025 LOCATION/POC: MCKM Thaddeus Brandt Engineer Petty Officer USCGSC Sturgeon Bay 85 PORT TERMINAL BLVD, SLIP 3 BAYONNE, NJ 07002 US (201) 912-7910 (work) (631) 655-4034 (personal)
CGC STURGEON BAY WATER MIST FIRE SUPRESSION TESTING WITH UPDATE SOW is a federal acquisition solicitation issued by DEPARTMENT OF HOMELAND SECURITY. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.
SamSearch Platform
AI-powered intelligence for the right opportunities, the right leads, and the right time.