Closed Solicitation · DEPT OF DEFENSE

    ENGINEERING JUDGEMENTS FOR 2-HOUR FIRE RATING

    Sol. N4008521C0051P000XXXSources SoughtNORFOLK, VA
    Closed
    STATUS
    Closed
    closed Jul 2, 2024
    POSTED
    Jun 18, 2024
    Publication date
    NAICS CODE
    236220
    Primary industry classification
    PSC CODE
    Y1ED
    Product & service classification

    AI Summary

    The Department of Defense, specifically the Department of the Navy, is seeking Engineering Judgements (EJs) from manufacturers of thin-film intumescent structural fire protection products. The goal is to achieve a 2-hour fire-resistance rating for steel structural members supporting a stair enclosure in a unique non-listed assembly application. Interested parties should provide EJs by the deadline of July 2, 2024, at 5:00 PM Eastern Time.

    Contract details

    Solicitation No.
    N4008521C0051P000XXX
    Notice Type
    Sources Sought
    Posted Date
    June 18, 2024
    Response Deadline
    July 2, 2024
    NAICS Code
    236220AI guide
    PSC / Class Code
    Y1ED
    Contract Code
    1700
    Issuing Office
    NAVFACSYSCOM ATLANTIC
    Primary Contact
    Brady Hammond
    State
    VA
    ZIP Code
    23508-1278

    Description

    Description: The U.S. Government is seeking information from manufacturers of thin-film intumescent structural fire protection products. Specifically, we request Engineering Judgements (EJs) for utilizing such products to achieve a 2-hour fire-resistance rating for steel structural members supporting a stair enclosure in a unique non-listed assembly application. Scope of Work: The application entails protecting structural steel columns and beams within an existing facility. The floor/ceiling assembly, supported by the beams, does not have, nor require, a fire-resistance rating and consists of steel plate welded atop the beams. The underside of the steel plate is exposed. The topside of the steel plate on top of the beams is exposed in some areas and covered with vinyl flooring (VCT) in others. Requirements: Fire-Resistance Rating: An EJ for a 2-hour fire-resistance rating is sought solely for the supporting structural members. No fire-resistance rating is required for the steel plate floor/ceiling/roof. Member Specifications: Steel Columns: W14X90 wide flange and HSS8x8x5/8 columns. Steel Beams: Ranging in size from W8x10 to W24x94. Steel Plate Floors/Ceiling and Roof: Thicknesses of 1/4 inch and 5/8 inch. Material Compatibility: The intumescent thin-film must be compatible with Amercoat 370 as a primer basecoat and PSX 700SG as a topcoat. Product Specification: The intumescent fire-resistant material must be an intumescent thin-film coating; intumescent paints are not acceptable as per UFC 3-600-01, Section 7-4.2.1.

    Key dates

    1. June 18, 2024Posted Date
    2. July 2, 2024Proposals / Responses Due

    Frequently asked questions

    ENGINEERING JUDGEMENTS FOR 2-HOUR FIRE RATING is a federal acquisition solicitation issued by DEPT OF DEFENSE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.