Closed Solicitation · DEPARTMENT OF THE INTERIOR

    F--ROY PRAY PORTAL REPAIRS

    Sol. 140L1725R0017Special NoticeSet-aside: 8(a) Sole Source (FAR 19.8)LAKEWOOD, CO
    Closed
    STATUS
    Closed
    closed Oct 21, 2025
    POSTED
    Sep 22, 2025
    Publication date
    NAICS CODE
    562910
    Primary industry classification
    PSC CODE
    F108
    Product & service classification

    AI Summary

    The Bureau of Land Management is planning to award a contract for the Roy Pray Portal Repairs, requiring excavation and installation of a new portal structure. An archaeological monitor will oversee the work to maintain the site's historic integrity. This notice is for information and planning purposes only.

    Contract details

    Solicitation No.
    140L1725R0017
    Notice Type
    Special Notice
    Set-Aside
    8(a) Sole Source (FAR 19.8)
    Posted Date
    September 22, 2025
    Response Deadline
    October 21, 2025
    NAICS Code
    562910AI guide
    PSC / Class Code
    F108
    Issuing Office
    COLORADO STATE OFFICE
    Primary Contact
    Nguyen, Chau
    State
    CO
    ZIP Code
    80225
    AI Product/Service
    service

    Description

    Roy Pray Portal Repairs
    SPECIAL NOTICE: THIS IS NOT A NOTICE OF SOLICITATION ISSUANCE. The Bureau of Land Management intends to issue an award to an 8(a) company named North Wind Construction Services, LLC, 1425 Higham St., Idaho Falls, ID 83402
    The Roy Pray Mine Site has been determined to be eligible for listing on the National Register of Historic Places (NRHP). A work plan will need to be developed that does not affect the site's eligibility and integrity. A BLM approved archaeological monitor will be required to monitor the activities.

    Excavate the portal area and then install a properly designed and constructed portal structure and replacement gate, with steel sets extending from approximately Station 0+84 to Station 1+12.5. It is recommended that these sets be lagged with steel channel or other steel material and that cavities overhead be filled with polyurea silicate void filling foam to prevent impact loading. As a matter of routine safety, the entire adit should be thoroughly scaled and afterwards, any rockfall or debris on the invert should be removed to eliminate unnecessary tripping hazards. Existing tripping hazards should be cleaned up as well. Rockbolting and meshing should be installed as an appropriate risk reduction measure to protect personnel during safety inspections.

    NAICS code is 562910 Remediation Services with size standard of $25 Mil. This Special Notice is issued solely for information and planning purposes. For questions, please contact Contract Specialist: Kerry Spetter via email at kspetter@blm.gov.

    Key dates

    1. September 22, 2025Posted Date
    2. October 21, 2025Proposals / Responses Due

    AI search tags

    Frequently asked questions

    F--ROY PRAY PORTAL REPAIRS is a federal acquisition solicitation issued by DEPARTMENT OF THE INTERIOR. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.