Closed Solicitation · DEPARTMENT OF HEALTH AND HUMAN SERVICES
AI Summary
The Haskell Indian Health Center requires the replacement of various exterior and interior doors, sidelights, and transoms, with specific technical requirements including UL 752 Level 5 bullet-resistant glazing. The project involves coordinating with the existing Secure Access Control provider and ensuring all doors are equipped with commercial-grade hardware. The solicitation is set aside for ISBEE and falls under NAICS Code 236220, with a submission deadline of July 7, 2025.
1. PURPOSE OF THE PROJECT The Haskell Indian Health Center (HIHC), Indian Health Services (IHS) has a requirement for the replacement of (4) existing exterior entryway doors, (4) interior entryway doors, and the sidelights and transoms for all (4) vestibules. 2. DETAILED DESCRIPTION OF THE TECHNICAL REQUIREMENTS The interior and exterior doors shall be 42 wide to accommodate gurneys used by EMS and wide wheelchairs. All exterior doors shall have a full window/daylight panel measuring approximately 34x 69 and be UL 752 Level 5 bullet resistant glazing or equivalent. All exterior glazing (door, transom, sidelights, exterior vestibule) shall be UL 752 Level 5 bullet resistant glazing or equivalent, except where noted in the scope of work. Interior glazing (door, transom, sidelights) shall be ¼ tempered glass. The northwest corner of the building has an existing metal and glass vestibule protruding from the building measuring approximately 36 out from the building and 64 wide. The (2) panes of glass on the exterior vestibule measure approximately 30x 90. These panes of glass shall be replaced with UL Level 5 bullet resistant glazing or equivalent. Within this vestibule there shall be a left hand reverse exterior door measuring 42x 84. The transom window shall be 4x 42 and shall be 1/4 tempered glass. The interior door, leading from the vestibule to the Pediatric/Behavior Health (north) hallway, shall be a left hand reverse door measuring 42x 84 with (2) sidelights measuring approximately 8 x 100 and a transom measuring approximately 16 x 42. The far west entryway leading to the Medical Staff hallway shall have a left hand reverse exterior door measuring 42x 84 with (2) sidelights measuring approximately 14x 100and a transom measuring approximately 16x 42. The interior door shall be a left hand reverse door measuring 42x 84 with (2) sidelights measuring approximately 15x 100 and a transom measuring approximately 16x 42. The south/southwest entryway in the breezeway between the Main Building and Wellness Center shall have a right hand reverse exterior door measuring 42x 84 with (1) sidelight measuring approximately 13x 101 and a transom measuring approximately 17x 42. The interior door shall be a right hand reverse door measuring 42x 84 with (2) sidelights measuring approximately 5x 100 and a transom measuring approximately 16x 42. The south entryway near the kitchen shall have a left hand reverse exterior door measuring 42x 84 with (2) sidelights measuring approximately 15x 100 and a transom measuring approximately 17x 42. The interior door shall be a left hand reverse door measuring 42x 84 with (2) sidelights measuring approximately 15x 100 and a transom measuring approximately 16x 42. Contractor shall coordinate with the facilitys existing Secure Access Control provider (Cam-Dex Security Corp.) to remove and replace the wires, card readers, and electronically operated door strikes back to original locations or as close as possible for all replaced doors. Card readers and strikes shall be in good working order before starting on the next exterior door for security purposes and to justify egress. Door and window frames shall be black anodized aluminum and match the fit and finish of the current frames. All doors, interior and exterior, shall be equipped with a commercial grade LCN door closer, panic bar, heavy-duty continuous hinge with threshold, and lock keyed to the facility master key. All exterior doors, sidelights and transoms shall be tinted with a mirror tint that is reflective when viewed from the exterior. In addition, the same tint shall be applied to the front (east), exterior, automatic sliding door entrance. Tinting shall be minimum of 35% shade. All (4) exterior doors shall be equipped with awnings that span the width of the exterior frame to cover persons entering and exiting the building. The awnings shall be black anodized aluminum (or equivalent metal) to match the fit and finish of the exterior frames. The awnings shall not extend more than 36 away from the building. All awnings shall be equipped with gutters and downspouts to divert water away from the building.
HASKELL IHS - VESTIBULE DOORS, SIDELIGHTS, AND TRANSOMS REPLACEMENT is a federal acquisition solicitation issued by DEPARTMENT OF HEALTH AND HUMAN SERVICES. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.
SamSearch Platform
AI-powered intelligence for the right opportunities, the right leads, and the right time.