Closed Solicitation · DEPARTMENT OF VETERANS AFFAIRS

    J059--UPGRADE OIT SERVER PANELS DCVAMC SEE DESCRIPTION FOR FULL DETAILS SDVOSB

    DEPARTMENT OF VETERANS AFFAIRS
    Sol. 36C24525Q0814Sources SoughtSet-aside: Veteran-Owned Small Business Set-Aside (specific to Department of Veterans Affairs)LINTHICUM, MD
    Closed
    STATUS
    Closed
    closed Sep 3, 2025
    POSTED
    Aug 26, 2025
    Publication date
    NAICS CODE
    238210
    Primary industry classification
    PSC CODE
    J059
    Product & service classification

    AI Summary

    The Department of Veterans Affairs is seeking responses from qualified entities for upgrading the electrical panels in the OIT Server Room at the Washington DC VA Medical Center. Interested parties should provide their capabilities, experience, and relevant certifications by September 3, 2025. This opportunity is set aside for SDVOSB and falls under FAR Part 13 procedures.

    Contract details

    Solicitation No.
    36C24525Q0814
    Notice Type
    Sources Sought
    Set-Aside
    Veteran-Owned Small Business Set-Aside (specific to Department of Veterans Affairs)
    Posted Date
    August 26, 2025
    Response Deadline
    September 3, 2025
    NAICS Code
    238210AI guide
    PSC / Class Code
    J059
    Primary Contact
    William Chris Galletta
    State
    MD
    ZIP Code
    21090
    AI Product/Service
    service

    Description

    Department of Veterans Affairs NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources, capabilities, and qualifications necessary to provide the services required for Washington DC VA Medical Center. Please respond to this RFI/Sources Sought 36C24525Q0814 with your: 1. Business name (including Unique Entity ID (SAM.gov) 2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), and 3. Person of contact (including telephone number & email address). 4. Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities. 5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include applicable NAICS) 6. Brief Summary of categories of services that your company can/cannot provide. 7. Certification(s) / Licenses for meeting the local requirements to provide these services at the Huntington VAMC (if applicable) 8. Confirmation that your organization has the capability & expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response: a. Do you intend to self-perform this effort? b. If you are located outside the immediate area, how will you self-perform? c. Or do you intend to subcontract work under this contract? d. If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting? Response Instructions: Responses must be received by Friday 9/03/ 2025 @ 10:00 AM EST. Responses to the information requested above must be submitted via email to William.Galletta@va.gov OIT Server Room Panel Upgrade Washington DC VA Medical Center 50 Irving St NW, Washington, DC 20422 1.0 INTRODUCTION This Statement of Work (SOW) outlines the requirements for upgrading the electrical panel(s) serving the Office of Information and Technology (OIT) Server Room at the Washington DC VA Medical Center. The upgrade is necessary to support current and future power demands, improve system reliability, and ensure compliance with all applicable codes and VA standards. 2.0 SCOPE OF WORK The contractor shall provide all labor, materials, equipment, supervision, testing, and incidentals required in: - Survey the existing server room electrical panel(s) and associated infrastructure. - Remove and properly dispose of existing panel(s) and associated components as required. - Furnish and install new electrical panel(s) of appropriate capacity and configuration, as specified by VA OIT and Engineering. - Integrate new panel(s) with existing electrical distribution systems, including all required connections, breakers, and labeling. - Ensure compatibility with existing and planned IT equipment loads. - Minimize server room downtime and coordinate all outages with VA OIT and Engineering. - Test and commission the new panel(s) and provide all required documentation. 3.0 DETAILED TASKS & INSTRUCTIONS 3.1 Pre-Installation Activities - Attend a pre-installation meeting with VA OIT and Engineering staff. - Conduct a detailed site survey to assess existing conditions and finalize panel requirements. - Submit product data, electrical drawings, and cut sheets for proposed panels and components for VA approval. - Develop and submit a project schedule, phasing plan, and safety plan for review. 3.2 Demolition and Removal - Shut down and lock out/tag out (LOTO) circuits and equipment in accordance with VA and OSHA standards. - Remove existing electrical panel(s) and associated components as required. - Properly dispose of all removed materials in compliance with environmental and VA regulations. 3.3 Installation of New Panel(s) - Prepare mounting surfaces and install new panel(s) and all required support. - Install all the new breakers, bus bars, and accessories as specified. - Integrate panel(s) with existing circuits, feeders, and grounding systems. - Ensure all the wiring is neat, labeled, and installed to NEC and VA standards. - Coordinate with VA OIT to minimize disruption to server room operations. 3.4 Testing and Commissioning - Inspect and test all new installations for proper operation, including load testing, breaker function, and grounding. - Verify compatibility with all server room equipment and confirm power redundancy as applicable. - Document all test results and submit to VA for review. 3.5 Project Closeout - Provide as-built drawings, updated panel schedules, and equipment submittals. - Submit warranty documentation for all new equipment. - Clean all work areas and remove debris. - Provide training for VA OIT and Engineering staff on operation and maintenance of the new panel(s). 4.0 DELIVERABLES - Project schedule, phasing plan, and safety plan. - Submittals for all equipment and materials. - Test and commissioning reports. - As-built drawings and updated panel schedules. - Warranty certificates and O&M manuals. 5.0 CONTRACTOR QUALIFICATIONS - Licensed electrical contractor with demonstrated experience in data center/server room environments. - All work to be performed by qualified, licensed electricians. - OSHA 30-hour certified supervisor to always be on site. 6.0 SAFETY & SECURITY - Comply with all VA, OSHA, and NEC safety requirements. - Maintain secure work areas and always protect sensitive IT equipment. - Implement infection control and dust mitigation measures as required. 7.0 COORDINATION & SCHEDULING - All work affecting server room operations must be coordinated with VA OIT and Engineering. - Schedule all outages and major activities during approved windows to minimize impact on operations.

    Key dates

    1. August 26, 2025Posted Date
    2. September 3, 2025Proposals / Responses Due