Closed Solicitation · DEPARTMENT OF VETERANS AFFAIRS

    J072--SOURCES SOUGHT NOTICE FOR CONTRACTOR TO REPAIR 3 RF SHIELDED DOORS FOR THE MRI DEPARTMENT WASHINGTON DC VA MEDICAL CENTER 36C24526Q0351

    DEPARTMENT OF VETERANS AFFAIRS
    Sol. 36C24526Q0351Sources SoughtLINTHICUM, MD
    Closed
    STATUS
    Closed
    closed Mar 19, 2026
    POSTED
    Mar 9, 2026
    Publication date
    NAICS CODE
    238290
    Primary industry classification
    PSC CODE
    J072
    Product & service classification

    AI Summary

    The Department of Veterans Affairs is seeking contractors for the repair of three RF shielded doors at the Washington DC VA Medical Center's MRI department. Interested vendors should provide their capabilities and relevant experience by the specified deadline. This notice is for planning purposes only and does not constitute a solicitation.

    Contract details

    Solicitation No.
    36C24526Q0351
    Notice Type
    Sources Sought
    Posted Date
    March 9, 2026
    Response Deadline
    March 19, 2026
    NAICS Code
    238290AI guide
    PSC / Class Code
    J072
    Primary Contact
    Bill Pratt
    State
    MD
    ZIP Code
    21090
    AI Product/Service
    service

    Description

    SUMMARY: Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 5, is issuing this request for sources sought notice in order to identify vendors that are interested in and capable of providing contractor services. For a contractor to repair 3 RF Shielded Doors for the Washington DC VAMC. Doors are for the MRI department. Review last page for details on how to respond to this Sources Sought Notice. Scope of Work: Project Title: Repair of Three RF Shielded Doors Location: Washington DC VA Medical Center, 50 Irving Street NW, Washington, DC 20422 Reference: MRI 26-163 1. Background: The Washington DC VA Medical Center requires maintenance and repair services for three (3) RF shielded doors located within the facility. These doors are critical for maintaining the integrity of MRI operations and ensuring proper shielding. 2. Scope of Work: Universal Shielding Corp will perform the following services: Door 1: Replace latching mechanism (includes bearings) Clean, align, and lubricate the door Door 2 & Door 3: Replace perimeter fingerstock and sill fingerstock Replace all bearings Clean, align, and lubricate both doors 3. Period of Performance: The total estimated duration for the work is approximately 4 hours per door, totaling 12 hours for all three doors. 4. Contractor Requirements: Provide all necessary labor, tools, equipment, and materials. Perform work using two qualified technicians. Work to be completed during overtime hours as required. Ensure compliance with VA safety and security protocols. 5. Deliverables: Fully functional and properly shielded RF doors. Documentation of work performed. Please respond to this RFI/Sources Sought 36C24526Q0351 with your: 1. Business name (including Unique Entity ID (SAM.gov) 2. Business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), and 3. Person of contact (including telephone number & email address). 4. Capability statement and summary of previous experience providing these types of services for the Veterans Health Administration or other similar facilities. 5. Available contract vehicles (GSA FSS, etc.) for use by Department of VA (include applicable NAICS) 6. Brief Summary of categories of services that your company can/cannot provide. 7. Certification(s) / Licenses for meeting the local requirements to provide these services at the DC VAMC (if applicable) 8. Confirmation that your organization has the capability & expertise to meet the performance requirements while complying with applicable limitations in subcontracting by responding to the questions below with your response: a. Do you intend to self-perform this effort? b. If you are located outside the immediate area, how will you self-perform? c. Or do you intend to subcontract work under this contract? d. If you intend to subcontract work under this contract, how will you ensure compliance with the limitations on subcontracting? Response Instructions: Responses must be submitted ASP but NLT 10:00 AM (ET) 03-19-2026, Responses to the information requested above must be submitted via email to Bill Pratt at Billie.Pratt@va.gov. Respond: 36C24526Q0351 Sources Sought Notice | Company Name This request for information/sources sought notice is for planning purposes ONLY and does not constitute a solicitation, responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., SDVOSB/SDVOSB set-aside, small business set-aside, full and open

    Key dates

    1. March 9, 2026Posted Date
    2. March 19, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    J072--SOURCES SOUGHT NOTICE FOR CONTRACTOR TO REPAIR 3 RF SHIELDED DOORS FOR THE MRI DEPARTMENT WASHINGTON DC VA MEDICAL CENTER 36C24526Q0351 is a federal acquisition solicitation issued by DEPARTMENT OF VETERANS AFFAIRS. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.