Active Solicitation · DEPT OF DEFENSE

    Repair for Lantirn ATE 24

    Sol. FA8517-26-R-0560Sources SoughtSet-aside: No Set aside usedROBINS AFB, GA
    Open · 15d remaining
    DAYS TO CLOSE
    15
    closes May 8, 2026
    POSTED
    Apr 23, 2026
    Publication date
    NAICS CODE
    811219
    Primary industry classification
    PSC CODE
    5700
    Product & service classification

    AI Summary

    The Department of Defense is seeking potential sources for the repair of the Signal Generator, NSN: 6150-01-385-8223KV. This market research aims to identify qualified vendors for a 5-year repair strategy with an estimated quantity of 2 units per year. Interested parties should contact Cory Harris or Jonathan Spiers for further information.

    Contract details

    Solicitation No.
    FA8517-26-R-0560
    Notice Type
    Sources Sought
    Set-Aside
    No Set aside used
    Posted Date
    April 23, 2026
    Response Deadline
    May 8, 2026
    NAICS Code
    811219AI guide
    PSC / Class Code
    5700
    Contract Code
    5700
    Issuing Office
    FA8517 AFSC PZAAC
    Primary Contact
    Latonya Jackson
    State
    GA
    ZIP Code
    31098-1670
    AI Product/Service
    service

    Description

    The Government is conducting market research to identify potential sources that may possess the expertise, capabilities, and experience to successfully meet the qualification requirements to repair the NSN: 6150-01-385-8223KV, PN: 717720650-039, Signal Generator. NOUN NSN P/N Generator, Signal 6150-01-385-8223KV 717720650-039, This requirement is for repair services. Our repair services strategy is a 5-year effort and will continue through FY 31. The projected quantities will be Best Estimated Quantities (BEQ) of 2 per year. These items are in the Power Supply Test Station. The electrical Load bank is A set (bank) of electrical elements that are passive (resistive, inductive, capacitive) or active (motors, batteries). They are usually located adjacent to each other to form a consolidated set of any of these elements or any combination of them. A load bank is used to replace distributed or dispersed load elements contained in a power distribution system or electrical network for the purpose of providing a concentrated load. A load bank contains all the essential electrical characteristics necessary to terminate the circuit and functions in the same manner as the load which it is intended to replace. This description necessarily includes a bank of light bulbs or cone heating elements where energy conversion is primarily in the form of heat although visible radiant energy is the natural result of incandescent heating. Load banks are intended to cover a specific range of characteristics and normally operate at dc or at power frequencies 50, 60, or 400 hz ac. Load banks may be uninstrumented or complete with integral instrumentation and may also be furnished as skid or trailer mounted. Excludes test set, electrical (as modified). see also dummy load, electrical. The Government is conducting market research to identify potential sources that may possess the expertise, capabilities, and experience to successfully meet the qualification requirements to repair the NSN: 6150-01-385-8223KV, PN: 717720650-039, Signal Generator. NOUN NSN P/N Generator, Signal 6150-01-385-8223KV 717720650-039, This requirement is for repair services. Our repair services strategy is a 5-year effort and will continue through FY 31. The projected quantities will be Best Estimated Quantities (BEQ) of 2 per year. These items are in the Power Supply Test Station. The electrical Load bank is A set (bank) of electrical elements that are passive (resistive, inductive, capacitive) or active (motors, batteries). They are usually located adjacent to each other to form a consolidated set of any of these elements or any combination of them. A load bank is used to replace distributed or dispersed load elements contained in a power distribution system or electrical network for the purpose of providing a concentrated load. A load bank contains all the essential electrical characteristics necessary to terminate the circuit and functions in the same manner as the load which it is intended to replace. This description necessarily includes a bank of light bulbs or cone heating elements where energy conversion is primarily in the form of heat although visible radiant energy is the natural result of incandescent heating. Load banks are intended to cover a specific range of characteristics and normally operate at dc or at power frequencies 50, 60, or 400 hz ac. Load banks may be uninstrumented or complete with integral instrumentation and may also be furnished as skid or trailer mounted. Excludes test set, electrical (as modified). see also dummy load, electrical. CAGE CODE : 0DRX9 CONTACT INFORMATION (PRIMARY) - CORY HARRIS cory.harris.4@us.af.mil CONTACT INFORMATION (SECONDARY) - JONATHAN SPIERS jonathan.spiers.1@us.af.mil "THIS IS NOT A SOLICITATION. THIS IS FOR MARKET RESEARCH PURPOSES ONLY"

    Key dates

    1. April 23, 2026Posted Date
    2. May 8, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    Repair for Lantirn ATE 24 is a federal acquisition solicitation issued by DEPT OF DEFENSE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.