Closed Solicitation · DEPARTMENT OF HOMELAND SECURITY

    SEQUOIA DUAL POINT DAVIT REPAIR

    Sol. 70Z085Q250019226Special NoticeALAMEDA, CA
    Closed
    STATUS
    Closed
    closed Jun 6, 2025
    POSTED
    May 27, 2025
    Publication date
    NAICS CODE
    336611
    Primary industry classification
    PSC CODE
    J020
    Product & service classification

    AI Summary

    The U.S. Coast Guard is seeking a sole source contractor for the repair of the Wellin Lambie Davit System on the CGC Sequoia, following damage from a fire. The contract requires a senior service field technician for five weekdays to conduct inspections, repairs, and tests, with specific parts listed for replacement. The performance period is from June 9 to June 13, 2025, at a location to be determined. Interested bidders must ensure compliance with government regulations and provide qualified personnel.

    Contract details

    Solicitation No.
    70Z085Q250019226
    Notice Type
    Special Notice
    Posted Date
    May 27, 2025
    Response Deadline
    June 6, 2025
    NAICS Code
    336611AI guide
    PSC / Class Code
    J020
    Sub-Agency
    US COAST GUARD
    Primary Contact
    DONNA O'NEAL
    State
    CA
    ZIP Code
    94501
    AI Product/Service
    service

    Description

    THIS IS TO BE AWARDED SOLE SOURCE 

    STATEMENT OF WORK (SOW)

      

    1. BACKGROUND

    CGC SEQUOIA suffered a small Charlie Fire within a control panel for the Wellin Lambie Davit System. Several terminals, wires, and other components were damaged, and the DISCREP requires certified technical representatives from Wellin Lambie to conduct onsite troubleshooting, repairs, and function tests. At the request of the vendor, pictures can be sent for preliminary part requirement inquiry. Ship’s force were able to identify where the fire could have originated.

    1. REFERENCE

    N/A

    1. REQUIREMENTS

          1. TO PROVIDE (1) SENIOR SERVICE FIELD TECHNICIAN WORKING (8) HRS PER DAY FOR (5) WEEKDAYS ON BOARD USCGC SEQUOIA TO ACCOMPLISH WELIN LAMBIE DAVIT TWIN PIV 5.0B SYSTEM INSPECTION, REPAIR, AND TEST.
          2. PARTS:
            1. 1000-8 DIN RAIL COMPLETE ASSEMBLED -1
              1. 859-02697 HYGROSTAT -1
              2. 859-03030 RELAY -7
              3. 859-03031 RELAY BASE -7
              4. 859-03032 RELAY RETAINING CLIP -7
              5. 859-02640 TOP HAT DIN RAIL -1
              6. 859-02400 MODULAR TERMINAL -33
              7. 859-02401 MODULAR TERMINAL -18
              8. 859-02405 END CLAMP -5
              9. 859-02410 PARTITION -12
              10. 859-02437 JUMPER BAR INSULATED -5
              11. 859-02439 JUMPER BAR INSULATED -1
              12. 859-02443 JUMPER BAR INSULATED -1
              13. 859-02685 ANGLE BRACKETS -4
              14. 859-03135 PROTECTION MODULE -7
              15. 9999 FERRULES & NUMBERING -1

    1. 4.0 ADMINISTRATION.

    4.1 CONTRACTOR PERSONELL

    4.1.1 Qualified Personnel. 

    The Contractor shall provide qualified personnel and subject matter experts to perform all required tasks specified in this SOW.

    4.1.2 Employee Conduct

    Contractor employees shall present a professional appearance, and their conduct shall not reflect discredit upon the U.S. Government, and any involved Departments or Agencies.  Contractor employees shall comply with all applicable Government regulations, policies, and procedures (e.g., fire, safety, sanitation, environmental protection, security, “off limits” areas, wearing of parts of military uniforms, and possession of weapons) when visiting or working at Government facilities.

    4.1.3 Conflict of Interest. 

    The Contractor shall not employ any person who is an employee of the U.S. Government if that employment would, or would appear to cause, a conflict of interest.  The Contractor shall take appropriate precautions as delineated in the Federal Acquisition Regulation (FAR) to preclude actual or apparent conflicts of interest.

    4.1.4 Facility Access

    The contractor must provide a valid Real I.D.

    4.2 PERIOD OF PERFORMANCE.  

    09JUN2025-13JUN2025

    4.3 PLACE OF PERFORMANCE.

    Repair facility to be determined.

    5.0 USCG POC’S

    CGC SEQUOIA          

    2700 Omar Street

    Port Huron, MI 48060

    POC CWO Albert (Lee) Lowery, Engineer Officer

    (907) 487-5344

    Email: Albert.L.Lowery@uscg.mil

    Product Line Support:

    ENS Marcos Saldarriaga

    667-419-5729

    Marcos.A.Saldarriaga@uscg.mil

    Key dates

    1. May 27, 2025Posted Date
    2. June 6, 2025Proposals / Responses Due

    AI search tags

    Frequently asked questions

    SEQUOIA DUAL POINT DAVIT REPAIR is a federal acquisition solicitation issued by DEPARTMENT OF HOMELAND SECURITY. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.