Active Solicitation · DEPT OF DEFENSE

    Tionesta Dam Control Tower Concrete Repair

    Sol. W911WN26QA043SolicitationSet-aside: Total Small Business Set-Aside (FAR 19.5)PITTSBURGH, PA
    Open · 28d remaining
    DAYS TO CLOSE
    28
    closes Aug 10, 2026
    POSTED
    Jul 8, 2026
    Publication date
    NAICS CODE
    237990
    Primary industry classification
    PSC CODE
    Y1QA
    Product & service classification

    AI Summary

    The U.S. Army Corps of Engineers requires concrete repairs at the Tionesta Dam Control Tower to restore watertightness and ensure safe access. The project involves demolition of unsound concrete, installation of reinforcement, and application of a hydrophilic waterstop. This opportunity is a 100% Small Business Set-Aside, and interested contractors are encouraged to submit quotes.

    Contract details

    Solicitation No.
    W911WN26QA043
    Notice Type
    Solicitation
    Set-Aside
    Total Small Business Set-Aside (FAR 19.5)
    Posted Date
    July 8, 2026
    Response Deadline
    August 10, 2026
    NAICS Code
    237990AI guide
    PSC / Class Code
    Y1QA
    Contract Code
    2100
    Primary Contact
    Mario TAORMINA
    State
    PA
    ZIP Code
    15222-4198
    AI Product/Service
    service

    Description

    The U.S. Army Corps of Engineers, Pittsburgh District, requires repairs to a deteriorated section of concrete within the stairwell of the Intake Tower at Tionesta Creek Lake. The repair is necessary to restore watertightness, prevent inundation of interior spaces during high-water events, and maintain safe access for project personnel. The deteriorated section of concrete is located at elevation 1116.5 and encompasses an area approximately 8 feet high from elevation 1116.5, 7 feet wide from the right wall, and at least 8 inches deep, or until the contractor encounters sound concrete. The contractor shall sound the concrete, mark the limits of demolition, and remove all unsound material. After demolition, a non-shrink, low-pressure injection grout shall be installed around the full perimeter of the existing concrete to reduce seepage from the gatewell into the stairwell. Reinforcement shall be installed, which includes horizontal, vertical, and bent-hook bars that are doweled and epoxied into the existing structure. All reinforcement must maintain a minimum clear cover of three inches. A concrete bonding agent shall be applied to all existing surfaces. A hydrophilic waterstop shall be installed along all vertical and horizontal joints to minimize future leakage. Formwork shall be set flush with the existing wall face, and new concrete shall be placed and vibrated to ensure full consolidation and a uniform finish. The North American Industrial Classification Code (NAICS) is 237990 ? Other Heavy and Civil Engineering Construction. The Small Business Size Standard is $45,000,000.00. This procurement is a 100% Small Business Set-Aside. All interested and capable offerors are encouraged to submit a quote. Information regarding the U.S. Army Corps of Engineers process for settling requests for equitable adjustments and duration goals to achieve definitization of equitable adjustments for change orders under construction contracts can be found by going to https://www.usace.army.mil/Strategic-Partnerships/Partnering/mod/129895/details/443/ then scrolling down on right hand side of page by clicking on ?View FFP Contract Changes Playbook Here?.

    Key dates

    1. July 8, 2026Posted Date
    2. August 10, 2026Proposals / Responses Due