Active Solicitation · DEPARTMENT OF HOMELAND SECURITY

    USCG Station Bodega Bay Mess Deck and Comms Room Electrical

    Sol. 30462PR260000045SolicitationSet-aside: Total Small Business Set-Aside (FAR 19.5)ALAMEDA, CA
    Open · 4d remaining
    DAYS TO CLOSE
    4
    closes Jul 18, 2026
    POSTED
    Jul 13, 2026
    Publication date
    NAICS CODE
    238210
    Primary industry classification
    PSC CODE
    5975
    Product & service classification

    AI Summary

    The US Coast Guard is soliciting contractors for electrical services at Station Bodega Bay. The project involves correcting hazardous electrical conditions and installing new circuits in various rooms. The solicitation closing date is July 17, 2026, and site visits are scheduled for July 6 and 7, 2026. Offerors are encouraged to inspect the site prior to bidding.

    Contract details

    Solicitation No.
    30462PR260000045
    Notice Type
    Solicitation
    Set-Aside
    Total Small Business Set-Aside (FAR 19.5)
    Posted Date
    July 13, 2026
    Response Deadline
    July 18, 2026
    NAICS Code
    238210AI guide
    PSC / Class Code
    5975
    Contract Code
    7008
    Issuing Office
    BASE ALAMEDA(00031)
    Sub-Agency
    US COAST GUARD
    Primary Contact
    Anthony Ciurlino
    State
    CA
    ZIP Code
    94501
    AI Product/Service
    service

    Description

    AMENDMENT 001 is issued to revise the Statement of Work. See the Amended Solicitation document attachment. The solicitation closing date is changed to July 17, 2026. The Solicitation is for a contractor to furnish all labor, materials, tools, equipment, supervision, and incidentals necessary to correct hazardous electrical conditions and install new dedicated convenience outlet circuits serving the Watch Room, Mess Deck, Galley, COM Room, and associated attic spaces. Work should eliminate existing mis-wired conditions, resolve recurring breaker trips, and provide safe, code-compliant electrical service for mission-essential equipment. The facility is experiencing repeated circuit breaker trips and loss of power due to improperly wired and overloaded circuits originating from a junction box located in the Mess Deck CMU wall. Investigation revealed unsafe voltage conditions, including 240V supplied to 110V receptacles, absence of neutral and grounding conductors, evidence of arcing, and shared circuits supplying lighting and convenience outlets. Immediate temporary disconnect actions were taken for safety; permanent corrective action is required. Offerors or quoters are urged and expected to inspect the site where the work will be performed. Site visits will be available on Monday, July 6, 2026 and Tuesday, July 7, 2026. To coordinate please reach out to: MK1 Joshua Florez, 707-875-3596, or 760-702-2343.

    Key dates

    1. July 13, 2026Posted Date
    2. July 18, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    USCG Station Bodega Bay Mess Deck and Comms Room Electrical is a federal acquisition solicitation issued by DEPARTMENT OF HOMELAND SECURITY. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.