    The US Coast Guard requires a contractor for the cleaning and inspection of the R-102 Galley Fire Suppression System aboard the USCGC Alder. The contractor must provide all necessary personnel, tools, and materials to perform maintenance tasks, including cleaning, inspection, and repair. The period of performance is from April 19 to May 17, 2026.

    Contract details

    Solicitation No.
    70Z08536Q023738
    Notice Type
    Solicitation
    Set-Aside
    Total Small Business Set-Aside (FAR 19.5)
    Posted Date
    March 30, 2026
    Response Deadline
    April 7, 2026
    NAICS Code
    336611AI guide
    PSC / Class Code
    J020
    Sub-Agency
    US COAST GUARD
    Primary Contact
    McTague, Sean
    State
    CA
    ZIP Code
    94501
    AI Product/Service
    service

    Description

    TECHNICAL SERVICES FOR CLEAN AND INSPECTION OF R-102 GALLEY FIRE SUPPRESSION SYSTEM

    USCGC ALDER

    1. Background. This requirement is for the contractor to clean the galley hood and inspection of R-102 Galley Fire Suppression System.

    1. Scope. The Contractor shall provide all personnel including services, labor, materials, travel, parts, tools, test equipment, test fittings, supplies, consumables, and equipment to accomplish tasking. The Contractor shall provide the services of a qualified Tech Rep, who is familiar with the R-102 Galley Fire Suppression System system/equipment, to accomplish all tasking. The Tech Rep will be responsible for the following:
    • Advise on manufacturer's proprietary information pertinent to the system.
    • Assist with proper repair methods and ensure compliance with manufacturer's procedures and standards during disassembly, inspection, repair, modification, calibration, and reassembly of the equipment/system.
    • Ensure compliance with manufacturer's procedures and standards during disassembly, inspection, and reassembly of the system.
    • Exhaust Hood: The interior and exterior surfaces of the hood will be cleaned to bare metal. This includes the plenum, the area behind the filters.
    • Grease Filters: Filters will be removed, cleaned, and reinstalled. Damaged or worn filters should be reported to the client for replacement.
    • Ductwork: All accessible ductwork, both horizontal and vertical, will be cleaned to remove all grease buildup.
    • Condensate Drains: All condensate drains and collection points will be cleared of obstructions and cleaned to ensure proper drainage.

    1. Objective. The objective of this requirement is to complete annual maintenance on the system

    1. Tasks. The contractor shall provide labor and maintenance services IAW TP 3924-555-A, R-102 Restaurant Fire Suppression System, TP 4563B-555-A, Fire Suppression System-Model R-102, TP 7427-651-A, R-102 Restaurant Fire Suppression System, TP 8057-555-A, Range Hood Fire Fighting System R-102-1T-4N-6F, to include but not limited to:

    4.1. Clean

    4.2. Inspect

    4.3 Service

    4.4 Repair

    4.5 Certified

    1. Delivery. Contractor shall provide a final report within 3 days of contract period of performance.

    1. Government furnished property. None. Contractor will provide tools, expendables, and consumables.

    1. Security Requirement. Base access is required. Vendor shall have a valid driver’s license and show identification. A CG representative from the cutter will sponsor and escort vendor to the cutter.

    1. Place of performance- USCGC ALDER 1 Yerba Buena Island San Francisco, CA 94130

    1. Period of performance- April 19 to May 17 2026

    1. Points of Contact.

    10.1. USCG-SFLC-IBCTPLAPM2: CWO Keith Hoefer, Keith.A.Hoefer@uscg.mil, (571) 608-9238

    10.2. USCGC ALDER: CWO Chrisopher Laterza, Christopher.P.Laterza@uscg.mil  (415) 399-3590

    See also attachment.

    Key dates

    1. March 30, 2026Posted Date
    2. April 7, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    USCGC ALDER CLEAN AND INSPECTION OF R-102 GALLEY FIRE SS is a federal acquisition solicitation issued by DEPARTMENT OF HOMELAND SECURITY. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.