Closed Solicitation · DEPARTMENT OF VETERANS AFFAIRS

    Z1DA--REPLACE CONTAINMENT SUMP 610A4-25-503

    DEPARTMENT OF VETERANS AFFAIRS
    Sol. 36C25025Q0471SolicitationDAYTON, OH
    Closed
    STATUS
    Closed
    closed Jun 23, 2025
    POSTED
    Jun 17, 2025
    Publication date
    NAICS CODE
    236220
    Primary industry classification
    PSC CODE
    Z1DA
    Product & service classification

    AI Summary

    The Department of Veterans Affairs is soliciting bids for the replacement of a containment sump at the Fort Wayne facility, with a submission deadline of June 23, 2025. Bidders must comply with local waste management regulations, ensuring all outdoor waste receptacles are covered during the project. Additionally, the contractor must adhere to VA specifications for containment equipment and provide a temporary fuel tank for the generator during construction. Utility drawings are available for reference.

    Contract details

    Solicitation No.
    36C25025Q0471
    Notice Type
    Solicitation
    Posted Date
    June 17, 2025
    Response Deadline
    June 23, 2025
    NAICS Code
    236220AI guide
    PSC / Class Code
    Z1DA
    Primary Contact
    Stacie I Hill
    City
    DAYTON
    State
    OH
    ZIP Code
    45428

    Description

    Important additional information not provided in the original Statement of Work: All outdoor waste dumpsters/receptacles must be covered during the whole duration of the project to comply with Fort Wayne Code of Ordinances, Chapters 53, Sec. 53.41. All waste manifests, receipts, or documentation are forwarded to the COR. (Construction Debris, hazardous waste, etc.) The UST sensor, which is the yellow wire in the photo below, shall be replaced during this project. Answers to RFIs 1. When can the generator for Building 1 be out of service and for what duration? A: A temporary fuel tank will be required to serve the generator while work is taking place. 2. Are there any specifications on the new containment equipment? A: Yes the contractor must follow all VA tank Specifications as well as state, local, and any other regulatory agency requirements. 3. What is the depth of the existing containment pit? A: It is at minimum 8 inches deep but it was further below the ground in other areas. Exact depth is unknown. 4. Can utility drawings be provided for that area ? A: Yes. Please see attached. ATTACHMENTS 610A4-25-503 Replace Containment Sump Pre-Bid Sign in sheet FW 11 All Utilities

    Key dates

    1. June 17, 2025Posted Date
    2. June 23, 2025Proposals / Responses Due