SLED Opportunity · MISSOURI · LINCOLN COUNTY

    Addendum 3 (North 56th Street Pump Station

    Issued by Lincoln County
    countyNotice to BiddersLincoln CountySol. 17495
    Closed
    STATUS
    Closed
    due Feb 27, 2026
    PUBLISHED
    Jan 23, 2026
    Posting date
    JURISDICTION
    Lincoln County
    county
    NAICS CODE
    236220
    AI-classified industry

    AI Summary

    Lincoln County, Missouri issues a Notice to Bidders for construction services related to the North 56th Street Pump Station. The addendum clarifies materials, equipment specs, and installation details. Bid assistance is available by phone or online.

    Opportunity details

    Solicitation No.
    17495
    Type / RFx
    Notice to Bidders
    Status
    Issued
    Level
    county
    Published Date
    January 23, 2026
    Due Date
    February 27, 2026
    NAICS Code
    236220AI guide
    Jurisdiction
    Lincoln County
    Agency
    Lincoln County

    Description

    If you need assistance in preparing your bid, 1) Click the "Help" button in the upper right hand corner of any screen; or 2) Contact our office at 402-441-8103 to assistance over the phone. --- Q&A --- Q1: Please advise if KSB can be added as an approved equal via addendum. A1: This vendor is not included in the specification. Submitted: 2/20/2026 01:31:39 PM (CT) Q2: Can the Marvair PAC-101 be reviewed for proper specifications? Marvair vendor stating they don’t offer a variable compressor in the scheduled size. Please advise. A2: The Marvair PAC is acceptable. Variable compressors are not required. Schedule and notes on Sheet H-4 will be revised accordingly via addendum. Submitted: 2/17/2026 01:18:12 PM (CT) Q3: Is slag cment allowed for the grout mix?If slag cement can be used here, it will mitigate possible ASR reactivity. A3: Slag cement is not allowed in grout mixes. All concrete and grout mixes shall follow the materials indicated in the specifications and the changes noted in Addendum 3. Per Section 03300, slag may be used in concrete mix designs to replace a portion of the Portland cement as specified in Paragraph 2-1.01. Submitted: 2/17/2026 12:45:44 PM (CT) Q4: Will it be acceptable to provide all trims related to roof panel/fascia/soffit in the same gauge as roof panel itself? Please advise. A4: Yes, 24 gauge is acceptable. Submitted: 2/17/2026 11:23:07 AM (CT) Q5: The elevations and 3D rendering show 4’-0” panel lengths at the fascia. Please confirm if fascia will be running horizontally. A5: Fascia to be 12" to 16" vertical flush panels (Una-Clad U-500 or equal). Section 07415 is revised to reflect clarification via Addendum 3. Submitted: 2/17/2026 11:21:53 AM (CT)

    Key dates

    1. January 23, 2026Published
    2. February 27, 2026Responses Due

    AI classification tags

    Frequently asked questions

    SLED stands for State, Local, and Education. These are solicitations issued by state governments, counties, cities, school districts, utilities, and higher education institutions — as opposed to federal agencies.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.