SLED Opportunity · CALIFORNIA · CITY OF SANTA CLARITA
AI Summary
City of Santa Clarita seeks bids for the Hart Park Pool House Retaining Wall Replacement project, including removal and construction of retaining walls, concrete stairway reconstruction, and historic restoration of handrails and flagstone. The project requires various construction services and historic preservation work, with bids due by April 14, 2026.
This project includes the removal of an existing retaining wall and the construction of a new retaining wall near the Pool House at William S. Hart Regional Park. The work also includes reconstruction of the reinforced concrete staircase associated with the retaining wall area. Historic elements intended for restoration include the handrail, flagstone, and plaster, in accordance with the Secretary of the Interior’s Standards for the Treatment of Historic Properties. **Project Type**: IFB - Invitation for Bid (Formal) **Source ID**: PU.MU.USA.1480380.C17029476 **Piggyback Contract**: No **Question Acceptance Deadline**: 04/08/2026 02:00 PM EDT **Questions are submitted online**: Yes **Onsite Visit**: 03/31/2026 11:00 AM EDT **Bid Submission Type**: Electronic Bid Submission **Owner Organization**: CIP **Reference Number**: 0000416833 **Pricing**: Item Based **Bid Documents List**: | Item Name | Description | Mandatory | Limited to 1 file | |---|---|---|---| | Proposal Form | Proposal Form | Yes | No | | Notice to Bidders | Notice to Bidders Regarding Contractual Requirements | Yes | No | | Bidder’s Information and Certification | Bidder’s Information and Certification | Yes | No | | Bidder’s Questionnaire | Bidder’s Questionnaire | Yes | No | | Certification of Non-Segregated Facilities | Certification of Non-Segregated Facilities | Yes | No | | Designation of Subcontractors | Designation of Subcontractors | Yes | No | | References | References | Yes | No | | Non-Collusion Affidavit | Non-Collusion Affidavit | Yes | No | | All signed addendums (if any) | All signed addendums (if any) | No | No | | General Attachments | General Attachments | No | No | **Pre-Bidding Events**: Event Type: Prebid Conference | Attendance: Recommended | Event date: 03/23/2026 05:30 PM EDT | Location: ZOOM | Event Note: https://santaclarita.zoomgov.com/j/16019292633 (Passcode: 969400) Event Type: Onsite Visit | Attendance: Recommended | Event date: 03/31/2026 11:00 AM EDT | Location: Hart Park Pool House located at 24151 Newhall Ave, Santa Clarita, CA 91321 | Event Note: Hart Park Pool House located at 24151 Newhall Ave, Santa Clarita, CA 91321 **Line Items**: | Code | Description | UOM | Qty | |---|---|---|---| | Next Project 1 Next Bid Schedule-Line Item STANDARD Code Description UOM Qty 1 MOBILIZATION/DEMOILIZATION Lump-Sum 1 2 CONSTRUCTION SURVEY Lump-Sum 1 3 WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S Lump-Sum 1 4 CLEARING AND GRUBBING (LS) Lump-Sum 1 5 ROOT PRUNE TREE Each 1 6 PROTECTION OF EXISTING TREES TO REMAIN Each 1 7 STRUCTURE EXCAVATION Cubic Yard 80 8 REMOVE EXISTING RETAINING WALL Linear Foot/Feet 55 9 REMOVE EXISTING REINFORCED CONCRETE STAIRWAY Lump-Sum 1 10 REMOVE EXISTING CHAIN LINK FENCE Linear Foot/Feet 55 11 CONCRETE REMOVAL (NON-REINFORCED) Square Foot/Feet 460 12 REMOVE AND SALVAGE FLAGSTONE Square Foot/Feet 460 13 CONCRETE WALK, 4" THICK Square Foot/Feet 455 14 RESTORE SALVAGED FLAGSTONE Square Foot/Feet 455 15 PERVIOUS BACKFILL Cubic Yard 42 16 STRUCTURE BACKFILL Cubic Yard 6 17 WATERPROOFING MEMBRANE Square Foot/Feet 385 18 NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY Square Foot/Feet 480 19 PCC FOOTING FOR MASONRY RETAINING WALL Linear Foot/Feet 55 20 MASONRY RETAINING WALL Linear Foot/Feet 55 21 ROOT BARRIER Linear Foot/Feet 35 22 CATCH BASIN Each 2 23 CONCRETE DITCH (INCL WIRE MESH) Linear Foot/Feet 68 24 JACK 5" STEEL CASING Linear Foot/Feet 8 25 4" PVC PIPE Linear Foot/Feet 38 26 4" PERFORATED PVC PIPE Linear Foot/Feet 55 27 RIPRAP PAD Each 2 28 REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 Lump-Sum 1 29 METAL HAND RAILINGS (SPPWC STD PLAN 606) Linear Foot/Feet 25 30 REMOVE AND SALVAGE EXISTING HANDRAIL Linear Foot/Feet 13 31 REINSTALL SALVAGED HANDRAIL Linear Foot/Feet 13 32 CLEAN & PAINT EXISTING AND NEW HANDRAIL Linear Foot/Feet 46 | Next Bid Schedule-Line Item STANDARD Code Description UOM Qty 1 MOBILIZATION/DEMOILIZATION Lump-Sum 1 2 CONSTRUCTION SURVEY Lump-Sum 1 3 WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S Lump-Sum 1 4 CLEARING AND GRUBBING (LS) Lump-Sum 1 5 ROOT PRUNE TREE Each 1 6 PROTECTION OF EXISTING TREES TO REMAIN Each 1 7 STRUCTURE EXCAVATION Cubic Yard 80 8 REMOVE EXISTING RETAINING WALL Linear Foot/Feet 55 9 REMOVE EXISTING REINFORCED CONCRETE STAIRWAY Lump-Sum 1 10 REMOVE EXISTING CHAIN LINK FENCE Linear Foot/Feet 55 11 CONCRETE REMOVAL (NON-REINFORCED) Square Foot/Feet 460 12 REMOVE AND SALVAGE FLAGSTONE Square Foot/Feet 460 13 CONCRETE WALK, 4" THICK Square Foot/Feet 455 14 RESTORE SALVAGED FLAGSTONE Square Foot/Feet 455 15 PERVIOUS BACKFILL Cubic Yard 42 16 STRUCTURE BACKFILL Cubic Yard 6 17 WATERPROOFING MEMBRANE Square Foot/Feet 385 18 NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY Square Foot/Feet 480 19 PCC FOOTING FOR MASONRY RETAINING WALL Linear Foot/Feet 55 20 MASONRY RETAINING WALL Linear Foot/Feet 55 21 ROOT BARRIER Linear Foot/Feet 35 22 CATCH BASIN Each 2 23 CONCRETE DITCH (INCL WIRE MESH) Linear Foot/Feet 68 24 JACK 5" STEEL CASING Linear Foot/Feet 8 25 4" PVC PIPE Linear Foot/Feet 38 26 4" PERFORATED PVC PIPE Linear Foot/Feet 55 27 RIPRAP PAD Each 2 28 REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 Lump-Sum 1 29 METAL HAND RAILINGS (SPPWC STD PLAN 606) Linear Foot/Feet 25 30 REMOVE AND SALVAGE EXISTING HANDRAIL Linear Foot/Feet 13 31 REINSTALL SALVAGED HANDRAIL Linear Foot/Feet 13 32 CLEAN & PAINT EXISTING AND NEW HANDRAIL Linear Foot/Feet 46 | Code Description UOM Qty | 1 MOBILIZATION/DEMOILIZATION Lump-Sum 1 2 CONSTRUCTION SURVEY Lump-Sum 1 3 WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S Lump-Sum 1 4 CLEARING AND GRUBBING (LS) Lump-Sum 1 5 ROOT PRUNE TREE Each 1 6 PROTECTION OF EXISTING TREES TO REMAIN Each 1 7 STRUCTURE EXCAVATION Cubic Yard 80 8 REMOVE EXISTING RETAINING WALL Linear Foot/Feet 55 9 REMOVE EXISTING REINFORCED CONCRETE STAIRWAY Lump-Sum 1 10 REMOVE EXISTING CHAIN LINK FENCE Linear Foot/Feet 55 11 CONCRETE REMOVAL (NON-REINFORCED) Square Foot/Feet 460 12 REMOVE AND SALVAGE FLAGSTONE Square Foot/Feet 460 13 CONCRETE WALK, 4" THICK Square Foot/Feet 455 14 RESTORE SALVAGED FLAGSTONE Square Foot/Feet 455 15 PERVIOUS BACKFILL Cubic Yard 42 16 STRUCTURE BACKFILL Cubic Yard 6 17 WATERPROOFING MEMBRANE Square Foot/Feet 385 18 NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY Square Foot/Feet 480 19 PCC FOOTING FOR MASONRY RETAINING WALL Linear Foot/Feet 55 20 MASONRY RETAINING WALL Linear Foot/Feet 55 21 ROOT BARRIER Linear Foot/Feet 35 22 CATCH BASIN Each 2 23 CONCRETE DITCH (INCL WIRE MESH) Linear Foot/Feet 68 24 JACK 5" STEEL CASING Linear Foot/Feet 8 25 4" PVC PIPE Linear Foot/Feet 38 26 4" PERFORATED PVC PIPE Linear Foot/Feet 55 27 RIPRAP PAD Each 2 28 REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 Lump-Sum 1 29 METAL HAND RAILINGS (SPPWC STD PLAN 606) Linear Foot/Feet 25 30 REMOVE AND SALVAGE EXISTING HANDRAIL Linear Foot/Feet 13 31 REINSTALL SALVAGED HANDRAIL Linear Foot/Feet 13 32 CLEAN & PAINT EXISTING AND NEW HANDRAIL Linear Foot/Feet 46 | 1 | MOBILIZATION/DEMOILIZATION | Lump-Sum | 1 | 2 | CONSTRUCTION SURVEY | Lump-Sum | 1 | 3 | WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S | Lump-Sum | 1 | 4 | CLEARING AND GRUBBING (LS) | Lump-Sum | 1 | 5 | ROOT PRUNE TREE | Each | 1 | 6 | PROTECTION OF EXISTING TREES TO REMAIN | Each | 1 | 7 | STRUCTURE EXCAVATION | Cubic Yard | 80 | 8 | REMOVE EXISTING RETAINING WALL | Linear Foot/Feet | 55 | 9 | REMOVE EXISTING REINFORCED CONCRETE STAIRWAY | Lump-Sum | 1 | 10 | REMOVE EXISTING CHAIN LINK FENCE | Linear Foot/Feet | 55 | 11 | CONCRETE REMOVAL (NON-REINFORCED) | Square Foot/Feet | 460 | 12 | REMOVE AND SALVAGE FLAGSTONE | Square Foot/Feet | 460 | 13 | CONCRETE WALK, 4" THICK | Square Foot/Feet | 455 | 14 | RESTORE SALVAGED FLAGSTONE | Square Foot/Feet | 455 | 15 | PERVIOUS BACKFILL | Cubic Yard | 42 | 16 | STRUCTURE BACKFILL | Cubic Yard | 6 | 17 | WATERPROOFING MEMBRANE | Square Foot/Feet | 385 | 18 | NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY | Square Foot/Feet | 480 | 19 | PCC FOOTING FOR MASONRY RETAINING WALL | Linear Foot/Feet | 55 | 20 | MASONRY RETAINING WALL | Linear Foot/Feet | 55 | 21 | ROOT BARRIER | Linear Foot/Feet | 35 | 22 | CATCH BASIN | Each | 2 | 23 | CONCRETE DITCH (INCL WIRE MESH) | Linear Foot/Feet | 68 | 24 | JACK 5" STEEL CASING | Linear Foot/Feet | 8 | 25 | 4" PVC PIPE | Linear Foot/Feet | 38 | 26 | 4" PERFORATED PVC PIPE | Linear Foot/Feet | 55 | 27 | RIPRAP PAD | Each | 2 | 28 | REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 | Lump-Sum | 1 | 29 | METAL HAND RAILINGS (SPPWC STD PLAN 606) | Linear Foot/Feet | 25 | 30 | REMOVE AND SALVAGE EXISTING HANDRAIL | Linear Foot/Feet | 13 | 31 | REINSTALL SALVAGED HANDRAIL | Linear Foot/Feet | 13 | 32 | CLEAN & PAINT EXISTING AND NEW HANDRAIL | Linear Foot/Feet | 46 | | | | Next Bid Schedule-Line Item STANDARD Code Description UOM Qty 1 MOBILIZATION/DEMOILIZATION Lump-Sum 1 2 CONSTRUCTION SURVEY Lump-Sum 1 3 WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S Lump-Sum 1 4 CLEARING AND GRUBBING (LS) Lump-Sum 1 5 ROOT PRUNE TREE Each 1 6 PROTECTION OF EXISTING TREES TO REMAIN Each 1 7 STRUCTURE EXCAVATION Cubic Yard 80 8 REMOVE EXISTING RETAINING WALL Linear Foot/Feet 55 9 REMOVE EXISTING REINFORCED CONCRETE STAIRWAY Lump-Sum 1 10 REMOVE EXISTING CHAIN LINK FENCE Linear Foot/Feet 55 11 CONCRETE REMOVAL (NON-REINFORCED) Square Foot/Feet 460 12 REMOVE AND SALVAGE FLAGSTONE Square Foot/Feet 460 13 CONCRETE WALK, 4" THICK Square Foot/Feet 455 14 RESTORE SALVAGED FLAGSTONE Square Foot/Feet 455 15 PERVIOUS BACKFILL Cubic Yard 42 16 STRUCTURE BACKFILL Cubic Yard 6 17 WATERPROOFING MEMBRANE Square Foot/Feet 385 18 NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY Square Foot/Feet 480 19 PCC FOOTING FOR MASONRY RETAINING WALL Linear Foot/Feet 55 20 MASONRY RETAINING WALL Linear Foot/Feet 55 21 ROOT BARRIER Linear Foot/Feet 35 22 CATCH BASIN Each 2 23 CONCRETE DITCH (INCL WIRE MESH) Linear Foot/Feet 68 24 JACK 5" STEEL CASING Linear Foot/Feet 8 25 4" PVC PIPE Linear Foot/Feet 38 26 4" PERFORATED PVC PIPE Linear Foot/Feet 55 27 RIPRAP PAD Each 2 28 REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 Lump-Sum 1 29 METAL HAND RAILINGS (SPPWC STD PLAN 606) Linear Foot/Feet 25 30 REMOVE AND SALVAGE EXISTING HANDRAIL Linear Foot/Feet 13 31 REINSTALL SALVAGED HANDRAIL Linear Foot/Feet 13 32 CLEAN & PAINT EXISTING AND NEW HANDRAIL Linear Foot/Feet 46 | Code Description UOM Qty | 1 MOBILIZATION/DEMOILIZATION Lump-Sum 1 2 CONSTRUCTION SURVEY Lump-Sum 1 3 WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S Lump-Sum 1 4 CLEARING AND GRUBBING (LS) Lump-Sum 1 5 ROOT PRUNE TREE Each 1 6 PROTECTION OF EXISTING TREES TO REMAIN Each 1 7 STRUCTURE EXCAVATION Cubic Yard 80 8 REMOVE EXISTING RETAINING WALL Linear Foot/Feet 55 9 REMOVE EXISTING REINFORCED CONCRETE STAIRWAY Lump-Sum 1 10 REMOVE EXISTING CHAIN LINK FENCE Linear Foot/Feet 55 11 CONCRETE REMOVAL (NON-REINFORCED) Square Foot/Feet 460 12 REMOVE AND SALVAGE FLAGSTONE Square Foot/Feet 460 13 CONCRETE WALK, 4" THICK Square Foot/Feet 455 14 RESTORE SALVAGED FLAGSTONE Square Foot/Feet 455 15 PERVIOUS BACKFILL Cubic Yard 42 16 STRUCTURE BACKFILL Cubic Yard 6 17 WATERPROOFING MEMBRANE Square Foot/Feet 385 18 NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY Square Foot/Feet 480 19 PCC FOOTING FOR MASONRY RETAINING WALL Linear Foot/Feet 55 20 MASONRY RETAINING WALL Linear Foot/Feet 55 21 ROOT BARRIER Linear Foot/Feet 35 22 CATCH BASIN Each 2 23 CONCRETE DITCH (INCL WIRE MESH) Linear Foot/Feet 68 24 JACK 5" STEEL CASING Linear Foot/Feet 8 25 4" PVC PIPE Linear Foot/Feet 38 26 4" PERFORATED PVC PIPE Linear Foot/Feet 55 27 RIPRAP PAD Each 2 28 REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 Lump-Sum 1 29 METAL HAND RAILINGS (SPPWC STD PLAN 606) Linear Foot/Feet 25 30 REMOVE AND SALVAGE EXISTING HANDRAIL Linear Foot/Feet 13 31 REINSTALL SALVAGED HANDRAIL Linear Foot/Feet 13 32 CLEAN & PAINT EXISTING AND NEW HANDRAIL Linear Foot/Feet 46 | 1 | MOBILIZATION/DEMOILIZATION | Lump-Sum | 1 | 2 | CONSTRUCTION SURVEY | Lump-Sum | 1 | 3 | WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S | Lump-Sum | 1 | 4 | CLEARING AND GRUBBING (LS) | Lump-Sum | 1 | 5 | ROOT PRUNE TREE | Each | 1 | 6 | PROTECTION OF EXISTING TREES TO REMAIN | Each | 1 | 7 | STRUCTURE EXCAVATION | Cubic Yard | 80 | 8 | REMOVE EXISTING RETAINING WALL | Linear Foot/Feet | 55 | 9 | REMOVE EXISTING REINFORCED CONCRETE STAIRWAY | Lump-Sum | 1 | 10 | REMOVE EXISTING CHAIN LINK FENCE | Linear Foot/Feet | 55 | 11 | CONCRETE REMOVAL (NON-REINFORCED) | Square Foot/Feet | 460 | 12 | REMOVE AND SALVAGE FLAGSTONE | Square Foot/Feet | 460 | 13 | CONCRETE WALK, 4" THICK | Square Foot/Feet | 455 | 14 | RESTORE SALVAGED FLAGSTONE | Square Foot/Feet | 455 | 15 | PERVIOUS BACKFILL | Cubic Yard | 42 | 16 | STRUCTURE BACKFILL | Cubic Yard | 6 | 17 | WATERPROOFING MEMBRANE | Square Foot/Feet | 385 | 18 | NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY | Square Foot/Feet | 480 | 19 | PCC FOOTING FOR MASONRY RETAINING WALL | Linear Foot/Feet | 55 | 20 | MASONRY RETAINING WALL | Linear Foot/Feet | 55 | 21 | ROOT BARRIER | Linear Foot/Feet | 35 | 22 | CATCH BASIN | Each | 2 | 23 | CONCRETE DITCH (INCL WIRE MESH) | Linear Foot/Feet | 68 | 24 | JACK 5" STEEL CASING | Linear Foot/Feet | 8 | 25 | 4" PVC PIPE | Linear Foot/Feet | 38 | 26 | 4" PERFORATED PVC PIPE | Linear Foot/Feet | 55 | 27 | RIPRAP PAD | Each | 2 | 28 | REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 | Lump-Sum | 1 | 29 | METAL HAND RAILINGS (SPPWC STD PLAN 606) | Linear Foot/Feet | 25 | 30 | REMOVE AND SALVAGE EXISTING HANDRAIL | Linear Foot/Feet | 13 | 31 | REINSTALL SALVAGED HANDRAIL | Linear Foot/Feet | 13 | 32 | CLEAN & PAINT EXISTING AND NEW HANDRAIL | Linear Foot/Feet | 46 | | | Code Description UOM Qty | | 1 MOBILIZATION/DEMOILIZATION Lump-Sum 1 2 CONSTRUCTION SURVEY Lump-Sum 1 3 WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S Lump-Sum 1 4 CLEARING AND GRUBBING (LS) Lump-Sum 1 5 ROOT PRUNE TREE Each 1 6 PROTECTION OF EXISTING TREES TO REMAIN Each 1 7 STRUCTURE EXCAVATION Cubic Yard 80 8 REMOVE EXISTING RETAINING WALL Linear Foot/Feet 55 9 REMOVE EXISTING REINFORCED CONCRETE STAIRWAY Lump-Sum 1 10 REMOVE EXISTING CHAIN LINK FENCE Linear Foot/Feet 55 11 CONCRETE REMOVAL (NON-REINFORCED) Square Foot/Feet 460 12 REMOVE AND SALVAGE FLAGSTONE Square Foot/Feet 460 13 CONCRETE WALK, 4" THICK Square Foot/Feet 455 14 RESTORE SALVAGED FLAGSTONE Square Foot/Feet 455 15 PERVIOUS BACKFILL Cubic Yard 42 16 STRUCTURE BACKFILL Cubic Yard 6 17 WATERPROOFING MEMBRANE Square Foot/Feet 385 18 NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY Square Foot/Feet 480 19 PCC FOOTING FOR MASONRY RETAINING WALL Linear Foot/Feet 55 20 MASONRY RETAINING WALL Linear Foot/Feet 55 21 ROOT BARRIER Linear Foot/Feet 35 22 CATCH BASIN Each 2 23 CONCRETE DITCH (INCL WIRE MESH) Linear Foot/Feet 68 24 JACK 5" STEEL CASING Linear Foot/Feet 8 25 4" PVC PIPE Linear Foot/Feet 38 26 4" PERFORATED PVC PIPE Linear Foot/Feet 55 27 RIPRAP PAD Each 2 28 REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 Lump-Sum 1 29 METAL HAND RAILINGS (SPPWC STD PLAN 606) Linear Foot/Feet 25 30 REMOVE AND SALVAGE EXISTING HANDRAIL Linear Foot/Feet 13 31 REINSTALL SALVAGED HANDRAIL Linear Foot/Feet 13 32 CLEAN & PAINT EXISTING AND NEW HANDRAIL Linear Foot/Feet 46 | 1 | MOBILIZATION/DEMOILIZATION | Lump-Sum | 1 | 2 | CONSTRUCTION SURVEY | Lump-Sum | 1 | 3 | WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S | Lump-Sum | 1 | 4 | CLEARING AND GRUBBING (LS) | Lump-Sum | 1 | 5 | ROOT PRUNE TREE | Each | 1 | 6 | PROTECTION OF EXISTING TREES TO REMAIN | Each | 1 | 7 | STRUCTURE EXCAVATION | Cubic Yard | 80 | 8 | REMOVE EXISTING RETAINING WALL | Linear Foot/Feet | 55 | 9 | REMOVE EXISTING REINFORCED CONCRETE STAIRWAY | Lump-Sum | 1 | 10 | REMOVE EXISTING CHAIN LINK FENCE | Linear Foot/Feet | 55 | 11 | CONCRETE REMOVAL (NON-REINFORCED) | Square Foot/Feet | 460 | 12 | REMOVE AND SALVAGE FLAGSTONE | Square Foot/Feet | 460 | 13 | CONCRETE WALK, 4" THICK | Square Foot/Feet | 455 | 14 | RESTORE SALVAGED FLAGSTONE | Square Foot/Feet | 455 | 15 | PERVIOUS BACKFILL | Cubic Yard | 42 | 16 | STRUCTURE BACKFILL | Cubic Yard | 6 | 17 | WATERPROOFING MEMBRANE | Square Foot/Feet | 385 | 18 | NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY | Square Foot/Feet | 480 | 19 | PCC FOOTING FOR MASONRY RETAINING WALL | Linear Foot/Feet | 55 | 20 | MASONRY RETAINING WALL | Linear Foot/Feet | 55 | 21 | ROOT BARRIER | Linear Foot/Feet | 35 | 22 | CATCH BASIN | Each | 2 | 23 | CONCRETE DITCH (INCL WIRE MESH) | Linear Foot/Feet | 68 | 24 | JACK 5" STEEL CASING | Linear Foot/Feet | 8 | 25 | 4" PVC PIPE | Linear Foot/Feet | 38 | 26 | 4" PERFORATED PVC PIPE | Linear Foot/Feet | 55 | 27 | RIPRAP PAD | Each | 2 | 28 | REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 | Lump-Sum | 1 | 29 | METAL HAND RAILINGS (SPPWC STD PLAN 606) | Linear Foot/Feet | 25 | 30 | REMOVE AND SALVAGE EXISTING HANDRAIL | Linear Foot/Feet | 13 | 31 | REINSTALL SALVAGED HANDRAIL | Linear Foot/Feet | 13 | 32 | CLEAN & PAINT EXISTING AND NEW HANDRAIL | Linear Foot/Feet | 46 | | | 1 | MOBILIZATION/DEMOILIZATION | Lump-Sum | 1 | | 2 | CONSTRUCTION SURVEY | Lump-Sum | 1 | | 3 | WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S | Lump-Sum | 1 | | 4 | CLEARING AND GRUBBING (LS) | Lump-Sum | 1 | | 5 | ROOT PRUNE TREE | Each | 1 | | 6 | PROTECTION OF EXISTING TREES TO REMAIN | Each | 1 | | 7 | STRUCTURE EXCAVATION | Cubic Yard | 80 | | 8 | REMOVE EXISTING RETAINING WALL | Linear Foot/Feet | 55 | | 9 | REMOVE EXISTING REINFORCED CONCRETE STAIRWAY | Lump-Sum | 1 | | 10 | REMOVE EXISTING CHAIN LINK FENCE | Linear Foot/Feet | 55 | | 11 | CONCRETE REMOVAL (NON-REINFORCED) | Square Foot/Feet | 460 | | 12 | REMOVE AND SALVAGE FLAGSTONE | Square Foot/Feet | 460 | | 13 | CONCRETE WALK, 4" THICK | Square Foot/Feet | 455 | | 14 | RESTORE SALVAGED FLAGSTONE | Square Foot/Feet | 455 | | 15 | PERVIOUS BACKFILL | Cubic Yard | 42 | | 16 | STRUCTURE BACKFILL | Cubic Yard | 6 | | 17 | WATERPROOFING MEMBRANE | Square Foot/Feet | 385 | | 18 | NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY | Square Foot/Feet | 480 | | 19 | PCC FOOTING FOR MASONRY RETAINING WALL | Linear Foot/Feet | 55 | | 20 | MASONRY RETAINING WALL | Linear Foot/Feet | 55 | | 21 | ROOT BARRIER | Linear Foot/Feet | 35 | | 22 | CATCH BASIN | Each | 2 | | 23 | CONCRETE DITCH (INCL WIRE MESH) | Linear Foot/Feet | 68 | | 24 | JACK 5" STEEL CASING | Linear Foot/Feet | 8 | | 25 | 4" PVC PIPE | Linear Foot/Feet | 38 | | 26 | 4" PERFORATED PVC PIPE | Linear Foot/Feet | 55 | | 27 | RIPRAP PAD | Each | 2 | | 28 | REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 | Lump-Sum | 1 | | 29 | METAL HAND RAILINGS (SPPWC STD PLAN 606) | Linear Foot/Feet | 25 | | 30 | REMOVE AND SALVAGE EXISTING HANDRAIL | Linear Foot/Feet | 13 | | 31 | REINSTALL SALVAGED HANDRAIL | Linear Foot/Feet | 13 | | 32 | CLEAN & PAINT EXISTING AND NEW HANDRAIL | Linear Foot/Feet | 46 | **Line Items**: | Code | Description | UOM | Qty | |---|---|---|---| | Next Bid Schedule-Line Item STANDARD Code Description UOM Qty 1 MOBILIZATION/DEMOILIZATION Lump-Sum 1 2 CONSTRUCTION SURVEY Lump-Sum 1 3 WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S Lump-Sum 1 4 CLEARING AND GRUBBING (LS) Lump-Sum 1 5 ROOT PRUNE TREE Each 1 6 PROTECTION OF EXISTING TREES TO REMAIN Each 1 7 STRUCTURE EXCAVATION Cubic Yard 80 8 REMOVE EXISTING RETAINING WALL Linear Foot/Feet 55 9 REMOVE EXISTING REINFORCED CONCRETE STAIRWAY Lump-Sum 1 10 REMOVE EXISTING CHAIN LINK FENCE Linear Foot/Feet 55 11 CONCRETE REMOVAL (NON-REINFORCED) Square Foot/Feet 460 12 REMOVE AND SALVAGE FLAGSTONE Square Foot/Feet 460 13 CONCRETE WALK, 4" THICK Square Foot/Feet 455 14 RESTORE SALVAGED FLAGSTONE Square Foot/Feet 455 15 PERVIOUS BACKFILL Cubic Yard 42 16 STRUCTURE BACKFILL Cubic Yard 6 17 WATERPROOFING MEMBRANE Square Foot/Feet 385 18 NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY Square Foot/Feet 480 19 PCC FOOTING FOR MASONRY RETAINING WALL Linear Foot/Feet 55 20 MASONRY RETAINING WALL Linear Foot/Feet 55 21 ROOT BARRIER Linear Foot/Feet 35 22 CATCH BASIN Each 2 23 CONCRETE DITCH (INCL WIRE MESH) Linear Foot/Feet 68 24 JACK 5" STEEL CASING Linear Foot/Feet 8 25 4" PVC PIPE Linear Foot/Feet 38 26 4" PERFORATED PVC PIPE Linear Foot/Feet 55 27 RIPRAP PAD Each 2 28 REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 Lump-Sum 1 29 METAL HAND RAILINGS (SPPWC STD PLAN 606) Linear Foot/Feet 25 30 REMOVE AND SALVAGE EXISTING HANDRAIL Linear Foot/Feet 13 31 REINSTALL SALVAGED HANDRAIL Linear Foot/Feet 13 32 CLEAN & PAINT EXISTING AND NEW HANDRAIL Linear Foot/Feet 46 | Code Description UOM Qty | 1 MOBILIZATION/DEMOILIZATION Lump-Sum 1 2 CONSTRUCTION SURVEY Lump-Sum 1 3 WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S Lump-Sum 1 4 CLEARING AND GRUBBING (LS) Lump-Sum 1 5 ROOT PRUNE TREE Each 1 6 PROTECTION OF EXISTING TREES TO REMAIN Each 1 7 STRUCTURE EXCAVATION Cubic Yard 80 8 REMOVE EXISTING RETAINING WALL Linear Foot/Feet 55 9 REMOVE EXISTING REINFORCED CONCRETE STAIRWAY Lump-Sum 1 10 REMOVE EXISTING CHAIN LINK FENCE Linear Foot/Feet 55 11 CONCRETE REMOVAL (NON-REINFORCED) Square Foot/Feet 460 12 REMOVE AND SALVAGE FLAGSTONE Square Foot/Feet 460 13 CONCRETE WALK, 4" THICK Square Foot/Feet 455 14 RESTORE SALVAGED FLAGSTONE Square Foot/Feet 455 15 PERVIOUS BACKFILL Cubic Yard 42 16 STRUCTURE BACKFILL Cubic Yard 6 17 WATERPROOFING MEMBRANE Square Foot/Feet 385 18 NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY Square Foot/Feet 480 19 PCC FOOTING FOR MASONRY RETAINING WALL Linear Foot/Feet 55 20 MASONRY RETAINING WALL Linear Foot/Feet 55 21 ROOT BARRIER Linear Foot/Feet 35 22 CATCH BASIN Each 2 23 CONCRETE DITCH (INCL WIRE MESH) Linear Foot/Feet 68 24 JACK 5" STEEL CASING Linear Foot/Feet 8 25 4" PVC PIPE Linear Foot/Feet 38 26 4" PERFORATED PVC PIPE Linear Foot/Feet 55 27 RIPRAP PAD Each 2 28 REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 Lump-Sum 1 29 METAL HAND RAILINGS (SPPWC STD PLAN 606) Linear Foot/Feet 25 30 REMOVE AND SALVAGE EXISTING HANDRAIL Linear Foot/Feet 13 31 REINSTALL SALVAGED HANDRAIL Linear Foot/Feet 13 32 CLEAN & PAINT EXISTING AND NEW HANDRAIL Linear Foot/Feet 46 | 1 | MOBILIZATION/DEMOILIZATION | Lump-Sum | 1 | 2 | CONSTRUCTION SURVEY | Lump-Sum | 1 | 3 | WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S | Lump-Sum | 1 | 4 | CLEARING AND GRUBBING (LS) | Lump-Sum | 1 | 5 | ROOT PRUNE TREE | Each | 1 | 6 | PROTECTION OF EXISTING TREES TO REMAIN | Each | 1 | 7 | STRUCTURE EXCAVATION | Cubic Yard | 80 | 8 | REMOVE EXISTING RETAINING WALL | Linear Foot/Feet | 55 | 9 | REMOVE EXISTING REINFORCED CONCRETE STAIRWAY | Lump-Sum | 1 | 10 | REMOVE EXISTING CHAIN LINK FENCE | Linear Foot/Feet | 55 | 11 | CONCRETE REMOVAL (NON-REINFORCED) | Square Foot/Feet | 460 | 12 | REMOVE AND SALVAGE FLAGSTONE | Square Foot/Feet | 460 | 13 | CONCRETE WALK, 4" THICK | Square Foot/Feet | 455 | 14 | RESTORE SALVAGED FLAGSTONE | Square Foot/Feet | 455 | 15 | PERVIOUS BACKFILL | Cubic Yard | 42 | 16 | STRUCTURE BACKFILL | Cubic Yard | 6 | 17 | WATERPROOFING MEMBRANE | Square Foot/Feet | 385 | 18 | NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY | Square Foot/Feet | 480 | 19 | PCC FOOTING FOR MASONRY RETAINING WALL | Linear Foot/Feet | 55 | 20 | MASONRY RETAINING WALL | Linear Foot/Feet | 55 | 21 | ROOT BARRIER | Linear Foot/Feet | 35 | 22 | CATCH BASIN | Each | 2 | 23 | CONCRETE DITCH (INCL WIRE MESH) | Linear Foot/Feet | 68 | 24 | JACK 5" STEEL CASING | Linear Foot/Feet | 8 | 25 | 4" PVC PIPE | Linear Foot/Feet | 38 | 26 | 4" PERFORATED PVC PIPE | Linear Foot/Feet | 55 | 27 | RIPRAP PAD | Each | 2 | 28 | REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 | Lump-Sum | 1 | 29 | METAL HAND RAILINGS (SPPWC STD PLAN 606) | Linear Foot/Feet | 25 | 30 | REMOVE AND SALVAGE EXISTING HANDRAIL | Linear Foot/Feet | 13 | 31 | REINSTALL SALVAGED HANDRAIL | Linear Foot/Feet | 13 | 32 | CLEAN & PAINT EXISTING AND NEW HANDRAIL | Linear Foot/Feet | 46 | | | Code Description UOM Qty | | 1 MOBILIZATION/DEMOILIZATION Lump-Sum 1 2 CONSTRUCTION SURVEY Lump-Sum 1 3 WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S Lump-Sum 1 4 CLEARING AND GRUBBING (LS) Lump-Sum 1 5 ROOT PRUNE TREE Each 1 6 PROTECTION OF EXISTING TREES TO REMAIN Each 1 7 STRUCTURE EXCAVATION Cubic Yard 80 8 REMOVE EXISTING RETAINING WALL Linear Foot/Feet 55 9 REMOVE EXISTING REINFORCED CONCRETE STAIRWAY Lump-Sum 1 10 REMOVE EXISTING CHAIN LINK FENCE Linear Foot/Feet 55 11 CONCRETE REMOVAL (NON-REINFORCED) Square Foot/Feet 460 12 REMOVE AND SALVAGE FLAGSTONE Square Foot/Feet 460 13 CONCRETE WALK, 4" THICK Square Foot/Feet 455 14 RESTORE SALVAGED FLAGSTONE Square Foot/Feet 455 15 PERVIOUS BACKFILL Cubic Yard 42 16 STRUCTURE BACKFILL Cubic Yard 6 17 WATERPROOFING MEMBRANE Square Foot/Feet 385 18 NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY Square Foot/Feet 480 19 PCC FOOTING FOR MASONRY RETAINING WALL Linear Foot/Feet 55 20 MASONRY RETAINING WALL Linear Foot/Feet 55 21 ROOT BARRIER Linear Foot/Feet 35 22 CATCH BASIN Each 2 23 CONCRETE DITCH (INCL WIRE MESH) Linear Foot/Feet 68 24 JACK 5" STEEL CASING Linear Foot/Feet 8 25 4" PVC PIPE Linear Foot/Feet 38 26 4" PERFORATED PVC PIPE Linear Foot/Feet 55 27 RIPRAP PAD Each 2 28 REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 Lump-Sum 1 29 METAL HAND RAILINGS (SPPWC STD PLAN 606) Linear Foot/Feet 25 30 REMOVE AND SALVAGE EXISTING HANDRAIL Linear Foot/Feet 13 31 REINSTALL SALVAGED HANDRAIL Linear Foot/Feet 13 32 CLEAN & PAINT EXISTING AND NEW HANDRAIL Linear Foot/Feet 46 | 1 | MOBILIZATION/DEMOILIZATION | Lump-Sum | 1 | 2 | CONSTRUCTION SURVEY | Lump-Sum | 1 | 3 | WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S | Lump-Sum | 1 | 4 | CLEARING AND GRUBBING (LS) | Lump-Sum | 1 | 5 | ROOT PRUNE TREE | Each | 1 | 6 | PROTECTION OF EXISTING TREES TO REMAIN | Each | 1 | 7 | STRUCTURE EXCAVATION | Cubic Yard | 80 | 8 | REMOVE EXISTING RETAINING WALL | Linear Foot/Feet | 55 | 9 | REMOVE EXISTING REINFORCED CONCRETE STAIRWAY | Lump-Sum | 1 | 10 | REMOVE EXISTING CHAIN LINK FENCE | Linear Foot/Feet | 55 | 11 | CONCRETE REMOVAL (NON-REINFORCED) | Square Foot/Feet | 460 | 12 | REMOVE AND SALVAGE FLAGSTONE | Square Foot/Feet | 460 | 13 | CONCRETE WALK, 4" THICK | Square Foot/Feet | 455 | 14 | RESTORE SALVAGED FLAGSTONE | Square Foot/Feet | 455 | 15 | PERVIOUS BACKFILL | Cubic Yard | 42 | 16 | STRUCTURE BACKFILL | Cubic Yard | 6 | 17 | WATERPROOFING MEMBRANE | Square Foot/Feet | 385 | 18 | NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY | Square Foot/Feet | 480 | 19 | PCC FOOTING FOR MASONRY RETAINING WALL | Linear Foot/Feet | 55 | 20 | MASONRY RETAINING WALL | Linear Foot/Feet | 55 | 21 | ROOT BARRIER | Linear Foot/Feet | 35 | 22 | CATCH BASIN | Each | 2 | 23 | CONCRETE DITCH (INCL WIRE MESH) | Linear Foot/Feet | 68 | 24 | JACK 5" STEEL CASING | Linear Foot/Feet | 8 | 25 | 4" PVC PIPE | Linear Foot/Feet | 38 | 26 | 4" PERFORATED PVC PIPE | Linear Foot/Feet | 55 | 27 | RIPRAP PAD | Each | 2 | 28 | REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 | Lump-Sum | 1 | 29 | METAL HAND RAILINGS (SPPWC STD PLAN 606) | Linear Foot/Feet | 25 | 30 | REMOVE AND SALVAGE EXISTING HANDRAIL | Linear Foot/Feet | 13 | 31 | REINSTALL SALVAGED HANDRAIL | Linear Foot/Feet | 13 | 32 | CLEAN & PAINT EXISTING AND NEW HANDRAIL | Linear Foot/Feet | 46 | | | 1 | MOBILIZATION/DEMOILIZATION | Lump-Sum | 1 | | 2 | CONSTRUCTION SURVEY | Lump-Sum | 1 | | 3 | WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S | Lump-Sum | 1 | | 4 | CLEARING AND GRUBBING (LS) | Lump-Sum | 1 | | 5 | ROOT PRUNE TREE | Each | 1 | | 6 | PROTECTION OF EXISTING TREES TO REMAIN | Each | 1 | | 7 | STRUCTURE EXCAVATION | Cubic Yard | 80 | | 8 | REMOVE EXISTING RETAINING WALL | Linear Foot/Feet | 55 | | 9 | REMOVE EXISTING REINFORCED CONCRETE STAIRWAY | Lump-Sum | 1 | | 10 | REMOVE EXISTING CHAIN LINK FENCE | Linear Foot/Feet | 55 | | 11 | CONCRETE REMOVAL (NON-REINFORCED) | Square Foot/Feet | 460 | | 12 | REMOVE AND SALVAGE FLAGSTONE | Square Foot/Feet | 460 | | 13 | CONCRETE WALK, 4" THICK | Square Foot/Feet | 455 | | 14 | RESTORE SALVAGED FLAGSTONE | Square Foot/Feet | 455 | | 15 | PERVIOUS BACKFILL | Cubic Yard | 42 | | 16 | STRUCTURE BACKFILL | Cubic Yard | 6 | | 17 | WATERPROOFING MEMBRANE | Square Foot/Feet | 385 | | 18 | NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY | Square Foot/Feet | 480 | | 19 | PCC FOOTING FOR MASONRY RETAINING WALL | Linear Foot/Feet | 55 | | 20 | MASONRY RETAINING WALL | Linear Foot/Feet | 55 | | 21 | ROOT BARRIER | Linear Foot/Feet | 35 | | 22 | CATCH BASIN | Each | 2 | | 23 | CONCRETE DITCH (INCL WIRE MESH) | Linear Foot/Feet | 68 | | 24 | JACK 5" STEEL CASING | Linear Foot/Feet | 8 | | 25 | 4" PVC PIPE | Linear Foot/Feet | 38 | | 26 | 4" PERFORATED PVC PIPE | Linear Foot/Feet | 55 | | 27 | RIPRAP PAD | Each | 2 | | 28 | REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 | Lump-Sum | 1 | | 29 | METAL HAND RAILINGS (SPPWC STD PLAN 606) | Linear Foot/Feet | 25 | | 30 | REMOVE AND SALVAGE EXISTING HANDRAIL | Linear Foot/Feet | 13 | | 31 | REINSTALL SALVAGED HANDRAIL | Linear Foot/Feet | 13 | | 32 | CLEAN & PAINT EXISTING AND NEW HANDRAIL | Linear Foot/Feet | 46 | **Line Items**: | Code | Description | UOM | Qty | |---|---|---|---| | Code Description UOM Qty | | 1 MOBILIZATION/DEMOILIZATION Lump-Sum 1 2 CONSTRUCTION SURVEY Lump-Sum 1 3 WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S Lump-Sum 1 4 CLEARING AND GRUBBING (LS) Lump-Sum 1 5 ROOT PRUNE TREE Each 1 6 PROTECTION OF EXISTING TREES TO REMAIN Each 1 7 STRUCTURE EXCAVATION Cubic Yard 80 8 REMOVE EXISTING RETAINING WALL Linear Foot/Feet 55 9 REMOVE EXISTING REINFORCED CONCRETE STAIRWAY Lump-Sum 1 10 REMOVE EXISTING CHAIN LINK FENCE Linear Foot/Feet 55 11 CONCRETE REMOVAL (NON-REINFORCED) Square Foot/Feet 460 12 REMOVE AND SALVAGE FLAGSTONE Square Foot/Feet 460 13 CONCRETE WALK, 4" THICK Square Foot/Feet 455 14 RESTORE SALVAGED FLAGSTONE Square Foot/Feet 455 15 PERVIOUS BACKFILL Cubic Yard 42 16 STRUCTURE BACKFILL Cubic Yard 6 17 WATERPROOFING MEMBRANE Square Foot/Feet 385 18 NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY Square Foot/Feet 480 19 PCC FOOTING FOR MASONRY RETAINING WALL Linear Foot/Feet 55 20 MASONRY RETAINING WALL Linear Foot/Feet 55 21 ROOT BARRIER Linear Foot/Feet 35 22 CATCH BASIN Each 2 23 CONCRETE DITCH (INCL WIRE MESH) Linear Foot/Feet 68 24 JACK 5" STEEL CASING Linear Foot/Feet 8 25 4" PVC PIPE Linear Foot/Feet 38 26 4" PERFORATED PVC PIPE Linear Foot/Feet 55 27 RIPRAP PAD Each 2 28 REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 Lump-Sum 1 29 METAL HAND RAILINGS (SPPWC STD PLAN 606) Linear Foot/Feet 25 30 REMOVE AND SALVAGE EXISTING HANDRAIL Linear Foot/Feet 13 31 REINSTALL SALVAGED HANDRAIL Linear Foot/Feet 13 32 CLEAN & PAINT EXISTING AND NEW HANDRAIL Linear Foot/Feet 46 | 1 | MOBILIZATION/DEMOILIZATION | Lump-Sum | 1 | 2 | CONSTRUCTION SURVEY | Lump-Sum | 1 | 3 | WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S | Lump-Sum | 1 | 4 | CLEARING AND GRUBBING (LS) | Lump-Sum | 1 | 5 | ROOT PRUNE TREE | Each | 1 | 6 | PROTECTION OF EXISTING TREES TO REMAIN | Each | 1 | 7 | STRUCTURE EXCAVATION | Cubic Yard | 80 | 8 | REMOVE EXISTING RETAINING WALL | Linear Foot/Feet | 55 | 9 | REMOVE EXISTING REINFORCED CONCRETE STAIRWAY | Lump-Sum | 1 | 10 | REMOVE EXISTING CHAIN LINK FENCE | Linear Foot/Feet | 55 | 11 | CONCRETE REMOVAL (NON-REINFORCED) | Square Foot/Feet | 460 | 12 | REMOVE AND SALVAGE FLAGSTONE | Square Foot/Feet | 460 | 13 | CONCRETE WALK, 4" THICK | Square Foot/Feet | 455 | 14 | RESTORE SALVAGED FLAGSTONE | Square Foot/Feet | 455 | 15 | PERVIOUS BACKFILL | Cubic Yard | 42 | 16 | STRUCTURE BACKFILL | Cubic Yard | 6 | 17 | WATERPROOFING MEMBRANE | Square Foot/Feet | 385 | 18 | NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY | Square Foot/Feet | 480 | 19 | PCC FOOTING FOR MASONRY RETAINING WALL | Linear Foot/Feet | 55 | 20 | MASONRY RETAINING WALL | Linear Foot/Feet | 55 | 21 | ROOT BARRIER | Linear Foot/Feet | 35 | 22 | CATCH BASIN | Each | 2 | 23 | CONCRETE DITCH (INCL WIRE MESH) | Linear Foot/Feet | 68 | 24 | JACK 5" STEEL CASING | Linear Foot/Feet | 8 | 25 | 4" PVC PIPE | Linear Foot/Feet | 38 | 26 | 4" PERFORATED PVC PIPE | Linear Foot/Feet | 55 | 27 | RIPRAP PAD | Each | 2 | 28 | REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 | Lump-Sum | 1 | 29 | METAL HAND RAILINGS (SPPWC STD PLAN 606) | Linear Foot/Feet | 25 | 30 | REMOVE AND SALVAGE EXISTING HANDRAIL | Linear Foot/Feet | 13 | 31 | REINSTALL SALVAGED HANDRAIL | Linear Foot/Feet | 13 | 32 | CLEAN & PAINT EXISTING AND NEW HANDRAIL | Linear Foot/Feet | 46 | | | 1 | MOBILIZATION/DEMOILIZATION | Lump-Sum | 1 | | 2 | CONSTRUCTION SURVEY | Lump-Sum | 1 | | 3 | WATER POLLUTION CONTROL, IMPLEMENTATION AND MAINTENANCE OF BMP’S | Lump-Sum | 1 | | 4 | CLEARING AND GRUBBING (LS) | Lump-Sum | 1 | | 5 | ROOT PRUNE TREE | Each | 1 | | 6 | PROTECTION OF EXISTING TREES TO REMAIN | Each | 1 | | 7 | STRUCTURE EXCAVATION | Cubic Yard | 80 | | 8 | REMOVE EXISTING RETAINING WALL | Linear Foot/Feet | 55 | | 9 | REMOVE EXISTING REINFORCED CONCRETE STAIRWAY | Lump-Sum | 1 | | 10 | REMOVE EXISTING CHAIN LINK FENCE | Linear Foot/Feet | 55 | | 11 | CONCRETE REMOVAL (NON-REINFORCED) | Square Foot/Feet | 460 | | 12 | REMOVE AND SALVAGE FLAGSTONE | Square Foot/Feet | 460 | | 13 | CONCRETE WALK, 4" THICK | Square Foot/Feet | 455 | | 14 | RESTORE SALVAGED FLAGSTONE | Square Foot/Feet | 455 | | 15 | PERVIOUS BACKFILL | Cubic Yard | 42 | | 16 | STRUCTURE BACKFILL | Cubic Yard | 6 | | 17 | WATERPROOFING MEMBRANE | Square Foot/Feet | 385 | | 18 | NATURAL HYDRAULIC LIME (NHL) PLASTER ON MASONRY | Square Foot/Feet | 480 | | 19 | PCC FOOTING FOR MASONRY RETAINING WALL | Linear Foot/Feet | 55 | | 20 | MASONRY RETAINING WALL | Linear Foot/Feet | 55 | | 21 | ROOT BARRIER | Linear Foot/Feet | 35 | | 22 | CATCH BASIN | Each | 2 | | 23 | CONCRETE DITCH (INCL WIRE MESH) | Linear Foot/Feet | 68 | | 24 | JACK 5" STEEL CASING | Linear Foot/Feet | 8 | | 25 | 4" PVC PIPE | Linear Foot/Feet | 38 | | 26 | 4" PERFORATED PVC PIPE | Linear Foot/Feet | 55 | | 27 | RIPRAP PAD | Each | 2 | | 28 | REINFORCED CONCRETE STAIRWAY PER SPPWC STD PLAN 640 | Lump-Sum | 1 | | 29 | METAL HAND RAILINGS (SPPWC STD PLAN 606) | Linear Foot/Feet | 25 | | 30 | REMOVE AND SALVAGE EXISTING HANDRAIL | Linear Foot/Feet | 13 | | 31 | REINSTALL SALVAGED HANDRAIL | Linear Foot/Feet | 13 | | 32 | CLEAN & PAINT EXISTING AND NEW HANDRAIL | Linear Foot/Feet | 46 | **Questions and Answers**: - Q1 Arrow Right Question: Builder's Risk Can the Builder's Risk Requirement be waived? Arrow Right Answer: Yes, the Builder's Risk Requirement may be waived for this project. 04/03/2026 01:00 PM EDT 04/07/2026 02:19 PM EDT
SLED stands for State, Local, and Education. These are solicitations issued by state governments, counties, cities, school districts, utilities, and higher education institutions — as opposed to federal agencies.
SamSearch Platform
AI-powered intelligence for the right opportunities, the right leads, and the right time.