Active Solicitation · DEPARTMENT OF VETERANS AFFAIRS

    6515--NOTICE OF INTENT TO SOLE SOURCE NX EQ CRYOTHERAPY SYSTEMS: TISSUE ABLATION €“ CARDIAC

    DEPARTMENT OF VETERANS AFFAIRS
    Sol. 36C10X26R0028PresolicitationFREDERICK, MD
    Open · 15d remaining
    DAYS TO CLOSE
    15
    closes May 8, 2026
    POSTED
    Apr 23, 2026
    Publication date
    NAICS CODE
    339112
    Primary industry classification
    PSC CODE
    6515
    Product & service classification

    AI Summary

    The Department of Veterans Affairs intends to award a sole source contract to Medtronic USA, Inc. for the procurement of the Nitron CryoConsole Cardiac Cryoablation System. This system is essential for electrophysiology laboratories across VA medical centers, providing necessary installation, training, and maintenance services. Capability statements from interested parties are welcome, but no competitive proposals will be accepted.

    Contract details

    Solicitation No.
    36C10X26R0028
    Notice Type
    Presolicitation
    Posted Date
    April 23, 2026
    Response Deadline
    May 8, 2026
    NAICS Code
    339112AI guide
    PSC / Class Code
    6515
    Primary Contact
    Anthony Zibolski
    State
    MD
    ZIP Code
    21703
    AI Product/Service
    product

    Description

    Presolicitation Notice Presolicitation Notice Page 6 of 6 Presolicitation Notice *=Required Field Presolicitation Notice Page 1 of 6 The Department of Veterans Affairs (VA), Office of Procurement, Acquisition and Logistics, Strategic Acquisition Center (SAC), intends to award a sole source, firm fixed price requirements contract to Medtronic USA, Inc., 200 Medtronic Drive, Lafayette, CO 80026, for the procurement of the Medtronic Nitron CryoConsole Cardiac Cryoablation System, associated cryoballoon and focal catheters, installation, clinical and technical training, and OEM preventive maintenance and repair services. This action will support enterprise wide electrophysiology (EP) laboratory cardiac cryoablation capabilities across participating VA medical centers. The VA requires an FDA cleared, electrophysiology lab integrated cardiac cryoablation platform capable of performing both pulmonary vein isolation using cryoballoon catheters and focal cryoablation using OEM validated catheters on a single console. The system must include a cart based, closed loop nitrous oxide cryogen delivery console with real time pressure and temperature monitoring, automated safety interlocks, EP lab workflow integration, and compatibility with both cryoballoon and focal catheters from the same OEM. The platform must support facility installation, device qualification, staff training, and enterprise level OEM lifecycle service coverage to ensure safe, consistent operation across VA EP laboratories. Medtronic s Nitron CryoConsole, Arctic Front cryoballoon catheters, and Freezor focal catheters constitute the only FDA approved, OEM validated EP lab cryoablation ecosystem capable of meeting these requirements. Based on market research, including review of FDA cleared EP cryoablation technologies, available commercial systems, technical specifications, and current manufacturer product status, no other vendor produces an electrophysiology lab cryoballoon platform with a compatible focal catheter suite validated for use on a single console. No third party consoles or catheters are FDA validated for use with Medtronic s system, and use of non OEM components would fall outside FDA reviewed configurations. Accordingly, only Medtronic USA, Inc. can meet the VA s minimum clinical, enterprise standardization, and lifecycle sustainment requirements for an EP lab integrated cardiac cryoablation system. The applicable North American Industry Classification System (NAICS) code 339112 Surgical and Medical Instrument Manufacturing is most appropriate for this requirement. The size standard is 1,000 employees. The Product Service Code (PSC) is 6515 Medical and Surgical Instruments, Equipment, and Supplies. This notice of intent is not a request for competitive proposals. Interested parties may submit capability statements demonstrating that they can meet all of the Government s minimum requirements. Capability statements must include sufficient technical detail for consideration. The Government will review all responses received; however, a determination by the Government not to compete the proposed procurement based on any responses is solely within the Government s discretion. No solicitation is available at this time, and telephone inquiries will not be accepted. Points of contact are: Anthony Zibolski, Contracting Officer anthony.zibolski@va.gov Michael Andrews, Contract Specialist michael.andrews@va.gov

    Key dates

    1. April 23, 2026Posted Date
    2. May 8, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    6515--NOTICE OF INTENT TO SOLE SOURCE NX EQ CRYOTHERAPY SYSTEMS: TISSUE ABLATION €“ CARDIAC is a federal acquisition solicitation issued by DEPARTMENT OF VETERANS AFFAIRS. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.