Closed Solicitation · DEPARTMENT OF VETERANS AFFAIRS

    6515--ZIMMER BIOMET SURGICAL INSTRUMENTS

    DEPARTMENT OF VETERANS AFFAIRS
    Sol. 36C24126Q0461Sources SoughtTOGUS, ME
    Closed
    STATUS
    Closed
    closed May 11, 2026
    POSTED
    Apr 27, 2026
    Publication date
    NAICS CODE
    339112
    Primary industry classification
    PSC CODE
    6515
    Product & service classification

    AI Summary

    The Department of Veterans Affairs is seeking information on the availability of Zimmer Biomet surgical instruments for orthopedic procedures. This sources sought notice is for market research purposes only and does not constitute a solicitation. Interested firms must provide documentation of their capabilities and must be registered in SAM to be eligible for future contracts.

    Contract details

    Solicitation No.
    36C24126Q0461
    Notice Type
    Sources Sought
    Posted Date
    April 27, 2026
    Response Deadline
    May 11, 2026
    NAICS Code
    339112AI guide
    PSC / Class Code
    6515
    Primary Contact
    Kim McCarthy
    City
    TOGUS
    State
    ME
    ZIP Code
    04330
    AI Product/Service
    product

    Description

    THIS IS A SOURCES SOUGHT NOTICE ONLY: This announcement seeks information from the industry, which will be used for preliminary planning purposes for procurement. No proposals are being requested or accepted with this sources sought notice. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT SHALL BE AWARDED FROM THIS SOURCES SOUGHT NOTICE. THIS IS STRICTLY MARKET RESEARCH. The Department of Veterans Affairs Providence Healthcare System seeks to procure Zimmer Biomet knee surgical instruments and trays for routine and emergent orthopedic procedures in the Operating Room of Surgical Services. The agency intends to provide preference for domestic end products that are brand name or equal to Zimmer Biomet Surgical Instruments requested. The purpose of this synopsis is to gain knowledge of interest, capabilities, and qualifications of various members of industry, who have the capability to provide domestically produced brand name or equal surgical instruments that are compatible with Zimmer Biomet surgical implant prosthetics currently used in Providence VA. (See full list of instruments below) All interested firms must be registered in SAM (System for Award Management) to be eligible for the award of Government contracts. Interested parties responding to this Sources Sought request shall submit the following information at a minimum: (1) Company name and address point of contact with phone number and SAM UEI. (2) Documentation relating to performance capability, current point of contact, and phone number). (3) Socio-economic status to identify the business class as a large business, SDVOSB, VOSB, small business, Woman Owned, etc. (4) Place of manufacture (5) Any other pertinent company documentation prior to submission of offers to a solicitation. Any SD/VOSB firms responding to this Sources Sought Notice must also provide proof of registration in the SBA Vet Cert prior to submitting offers to a solicitation. This market research is for informational and planning purposes. This is not a solicitation and does not obligate the Government to issue a solicitation. Please be advised that the government will not pay any costs for responses and information submitted. All submissions are acceptable via kim.mccarthy@va.gov. RESULTS INFORMATION: Respondents will not be notified of the results, and it is at the discretion of the Government to utilize results. Firms responding to this Sources Sought announcement, who fail to meet all requirements as stated above, and who fail to provide ALL the required information requested, will not be used to help the Government make the acquisition decision, which is the intent of this sources sought announcement. Part Number (Set/Kit) Description Qty KT509700111 (FUZTN2) FUZION TENSOR, LEFT, ALUMBETA  1 KT509700112 (FUZTN3) FUZION TENSOR, RIGHT, ALUM BETA  1 597303202 (P2U) NEXGEN PATELLA REAMING COMPLETE INST KIT  1 KT593702031 (PFG207) PSN FEM/GEN P-REF KT SZ 4-12 1 KT593701061 (PFT114) PSN DRS/TRS 3/5/7 DEG KIT 1 KT444404004 (ECHOBP) ECHO ENDO BIPOLAR - CASE 4 INSTR KIT 1 KT444404002 (ECHOGEN) ECHO GENERAL - CASE 2 INSTR KIT 1 00-5907-080-79 CR FRM PROV LT SZ 5 CASE BRKT 1 00-5907-080-80 CR FRM PROV LT SZ 6 CASE BRKT 1 00-5907-080-81 CR FEM PROV LT SZ 7 CASE BRKT 1 00-5907-080-82 CR FRM PROV LT SZ 8 CASE BRKT 1 00-5907-080-83 CR FRM PROV LT SZ 9 CASE BRKT 1 00-5907-081-40 CR FRM PROV LT SZ 12 CASEBRKT 1 00-5907-081-61 CR FRM PROV LT SZ 4 CASE BRKT 1 00-5907-081-64 CR FRM PROV LT SZ 10 CASEBRKT 1 00-5907-081-65 CR FRM PROV LT SZ 11 CASEBRKT 1 42-5027-056-01 PSN CR FEM PROV SZ 4 L 1 42-5027-058-01 PERSONA CR FEMORAL PROVISIONAL SIZE 5 LEFT 1 42-5027-060-01 PERSONA CR FEMORAL PROVISIONAL SIZE 6 LEFT 1 42-5027-062-01 PERSONA CR FEMORAL PROVISIONAL SIZE 7 LEFT 1 42-5027-064-01 PERSONA CR FEMORAL PROVISIONAL SIZE 8 LEFT 1 42-5027-066-01 PERSONA CR FEMORAL PROVISIONAL SIZE 9 LEFT 1 42-5027-068-01 PERSONA CR FEMORAL PROVISIONAL SIZE 10 LEFT 1 42-5027-070-01 PERSONA CR FEMORAL PROVISIONAL SIZE 11 LEFT 1 42-5027-074-01 PSN CR FEM PROV SZ 12 L 1 42-5399-064-01 PERSONA CEMENTED TIBIAL SIZING PLATE LEFT SIZE C 1 42-5399-067-01 PERSONA CEMENTED TIBIAL SIZING PLATE LEFT SIZE D 1 42-5399-071-01 PERSONA CEMENTED TIBIAL SIZING PLATE LEFT SIZE E 1 42-5399-075-01 PERSONA CEMENTED TIBIAL SIZING PLATE LEFT SIZE F 1 42-5399-079-01 PERSONA CEMENTED TIBIAL SIZING PLATE LEFT SIZE G 1 42-5399-083-01 PERSONA CEMENTED TIBIAL SIZING PLATE LEFT SIZE H 1 00-5907-007-00 REMOVABLE SIDE PANEL 4 00-5907-007-01 REMOVABLE SIDE PANEL 4 00-5907-009-00 REMOVABLE END PANEL 4 00-5907-070-00 MODULAR SHELL LID GRAY 2 00-5907-071-00 ALUMINUM SINGLE-LEVEL SHE 2 00-5907-073-00 ALUMINUM FULL SIZE TRAY 2 00-5907-080-84 TASP AND SZ PLT CASE BRKT 1 00-5907-080-85 TASP AND SZ PLT CASE BRKT 1 00-5907-080-86 TASP AND SZ PLT CASE BRKT 1 42-5170-003-03 PERSONA TASP LEFT CD BOTTOM +0MM 1 42-5170-003-13 PERSONA TASP LEFT CD BOTTOM +6MM 1 42-5170-004-10 PERSONA TASP CR LEFT 3-9 CD TOP 1 42-5170-005-05 PERSONA TASP LEFT EF BOTTOM +0MM 1 42-5170-005-10 PERSONA TASP CR LEFT 3-11EF TOP 1 42-5170-005-15 PERSONA TASP LEFT EF BOTTOM +6MM 1 42-5170-006-10 PERSONA TASP CR LEFT 7-12GH TOP 1 42-5170-007-07 PERSONA TASP LEFT GH BOTTOM +0MM 1 42-5170-007-17 PERSONA TASP LEFT GH BOTTOM +6MM 1 00-5907-080-99 TASP AND SZ PLT GANG CASEBRKT 1 00-5907-081-00 TASP AND SZ PLT CASE BRKT 1 00-5907-081-01 TASP AND SZ PLT CASE BRKT 1 42-5270-003-03 PERSONA TASP RIGHT CD BOTTOM +0MM 1 42-5270-003-13 PERSONA TASP RIGHT CD BOTTOM +6MM 1 42-5270-004-10 PERSONA TASP CR RIGHT 3-9CD TOP 1 42-5270-005-05 PERSONA TASP RIGHT EF BOTTOM +0MM 1 42-5270-005-10 PERSONA TASP CR RIGHT 3-11 EF TOP 1 42-5270-005-15 PERSONA TASP RIGHT EF BOTTOM +6MM 1 42-5270-006-10 PERSONA TASP CR RIGHT 7-12 GH TOP 1 42-5270-007-07 PERSONA TASP RIGHT GH BOTTOM +0MM 1 42-5270-007-17 PERSONA TASP RIGHT GH BOTTOM +6MM 1

    Key dates

    1. April 27, 2026Posted Date
    2. May 11, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    6515--ZIMMER BIOMET SURGICAL INSTRUMENTS is a federal acquisition solicitation issued by DEPARTMENT OF VETERANS AFFAIRS. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.