Closed Solicitation · DEPARTMENT OF HEALTH AND HUMAN SERVICES

    Automated Dry Heat Diffusion System

    Sol. 75F40125Q00181Combined Synopsis/SolicitationBeltsville, MD
    Closed
    STATUS
    Closed
    closed May 30, 2025
    POSTED
    May 16, 2025
    Publication date
    NAICS CODE
    334516
    Primary industry classification
    PSC CODE
    6640
    Product & service classification

    AI Summary

    The Department of Health and Human Services, specifically the Food and Drug Administration, is seeking bids for an Automated Dry Heat Diffusion System with 24 vertical cells. This system will facilitate critical research on the performance, quality, and safety of transdermal and topical drug products through extensive diffusion studies lasting approximately 96 hours. The system must include automated mechanisms for sample collection and temperature control, essential for supporting the mission of the Division of Product Quality Research.

    Contract details

    Solicitation No.
    75F40125Q00181
    Notice Type
    Combined Synopsis/Solicitation
    Posted Date
    May 16, 2025
    Response Deadline
    May 30, 2025
    NAICS Code
    334516AI guide
    PSC / Class Code
    6640
    Contract Code
    7524
    Primary Contact
    Amanda Lusk
    State
    MD
    ZIP Code
    20705
    AI Product/Service
    product

    Description

    The Division of Product Quality Research (DPQR) conducts research on assessing the quality and safety of drug products. One of the on-going research activities is to conduct research on assessing the performance, quality and safety of transdermal and topical drug products. These studies are critical in assessing the quality of transdermal and topical drug delivery systems. To support this function, DPQR is requesting the acquisition of one (1) Automated Dry Heat Diffusion System with 24 vertical cells (or equivalent). This Automated Dry Heat Diffusion System will be used to perform diffusion studies that are approximately 96 hours and with large number of samples and repetitions to check the drug release and permeation across synthetic and biological barriers. This Automated Dry Heat Diffusion System and these diffusion studies will provide valuable information regarding safety, performance, and quality of transdermal and drug products and support CDER’s mission critical missions. The Automated Dry Heat Diffusion System with 24 vertical cells is used for studying the in vitro drug release and diffusion across various synthetic and biological barriers. This diffusion system has a heated donor and receiver compartments of the vertical diffusion cells with an automated mechanism to continuously collect and replace aliquot and whole media samples from all diffusion cells. This automated mechanism should also eliminate and expel any air bubbles that may be formed below the diffusion barrier during dosing and sampling throughout the study duration. This Automated Dry Heat Diffusion System is also equipped with sensors for direct measurement and control of donor and receiver chambers and barrier temperatures throughout the study duration.

    Key dates

    1. May 16, 2025Posted Date
    2. May 30, 2025Proposals / Responses Due

    AI search tags

    Frequently asked questions

    Automated Dry Heat Diffusion System is a federal acquisition solicitation issued by DEPARTMENT OF HEALTH AND HUMAN SERVICES. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.