    AI Summary

    The Department of Defense is seeking contractors to provide labor, materials, and equipment for the inspection and maintenance of the Barkley Lock Emergency Lift Gate machinery. This includes cleaning, disassembly, inspection, and reporting on various components, along with touch-up painting and necessary replacements. Initial and as-built reports are required.

    Contract details

    Solicitation No.
    W912P526QA023
    Notice Type
    Combined Synopsis/Solicitation
    Posted Date
    June 10, 2026
    Response Deadline
    July 10, 2026
    NAICS Code
    811310AI guide
    PSC / Class Code
    J039
    Contract Code
    2100
    Issuing Office
    W072 ENDIST NASHVILLE
    Primary Contact
    ROBERT ELLIS
    State
    TN
    ZIP Code
    37203-1070
    AI Product/Service
    service

    Description

    Contractor shall provide all labor, material, and equipment necessary to clean, disassemble/reassemble, and inspect all lifting machinery for the Barkley Lock Emergency Lift Gate, including but not limited to the limit switch assemblies, motors, enclosed gears, open gears, gear mounting assemblies, drums, sheaves, wire rope, brakes, shaft bearings, couplings, and control equipment. Provide the initial inspection reports with pictures of the equipment that show any deficiencies found during the inspection. Provide touch-up painting for all exterior surfaces of items in the scope of work after inspection except as otherwise noted. If a contract option is exercised, paint the respective components (except as otherwise noted) after the work in the contract option is completed. After completion, provide as-built reports that show as-built fits, backlashes, contact patterns and end floats. Initial inspection reports and as-built reports shall be required for all open gears, limit switch assemblies, and enclosed gears. Mark-up of the PDF for as-builts are acceptable. No CAD drawings shall be required for the as-builts. Provide new oil, grease, filters, fasteners, keys, and others as needed to get the Emergency Gate (E-Gate) machinery ready for operation.

    Key dates

    1. June 10, 2026Posted Date
    2. July 10, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    Barkley Emergency Gate Machinery Inspection is a federal acquisition solicitation issued by DEPT OF DEFENSE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.