The National Institute of Standards and Technology (NIST) is seeking sources for a high purity germanium detector with cryo-cooling and shielding. This equipment is essential for high energy resolution spectroscopy in semiconductor material analysis. Interested vendors should provide detailed product specifications and capabilities to meet NIST's requirements.
Title: Sources Sought Notice for Coincident gamma ray detection system, High purity germanium detector,
BACKGROUND
The semiconductor supply chain is global, specialized, and interconnected. Chipmakers do business with thousands of individual suppliers that provide the highly complex materials and tools used to produce semiconductors. To address the lack of full visibility into the semiconductors markets supply chain and R&D ecosystem gaps NIST will conduct the measurement science, or metrology, critical to the development of new materials, packaging, and production methods in chip manufacturing.
NIST seeks to procure a high purity germanium detector (HPGe) with cryo-cooling on transport cart with shielding sets and onboard efficiency calibration and software perpetual license. The detector system will be used in the neutron/gamma field generated by a portable neutron generator and the irradiated sample environment and connected by timing electronics with neutron/gamma detectors (separate procurement) for coincidence detection. Acquisition of high energy resolution prompt gamma spectrum from samples irradiated by thermal neutrons from a portable neutron generator and moderator, with absolute efficiency calibration for elemental quantification.
This is essential to perform high energy resolution spectroscopy as a part of coincidence detection system to minimize background gamma rays for improved signal to noise ratio and enhanced detection limit for critical elements in semiconductor material. Critical elements, especially light elements, such as H, B, N, in semiconductor material either intrinsic or added during manufacturing process can significantly affect the quality of the performance of the end product, in addition to metallic contaminants. PGAA is a unique non-destructive technique for quantitative analysis for these elements. PGAA is traditionally based on neutron beams from a nuclear reactor and therefore is less accessible to laboratory use. The proposed portable neutron generator-based PGAA, while 2 to 3 orders of magnitude lower in thermal neutron flux, can be suitable for elements of high capture cross sections, and through this project, demonstrate the potential for routine lab use that benefits the semiconductor industry.
The National Institute of Standards and Technology (NIST) is seeking information from sources that may be capable of providing a solution that will achieve the specifications described below:
Description: High purity Germanium detector with cryo-cooling and shielding
Quantity: One (1)
N-type coaxial HPGe detector with on-board cryo-cooling. Endcap diameter 3.00”. Al endcap window. Efficiency > 25%. Energy resolution WHM at 1332 keV < 2 keV. Peak to Compton ratio > 50. Transistor reset preamplifier. Complete with transport cart and collimator shielding. Self-contained efficiency calibration based on detector geometry.
HOW TO RESPOND TO THIS NOTICE
In responding to this notice, please DO NOT PROVIDE PROPRIETARY INFORMATION. Please include only the following information, readable in either Microsoft Word 365, Microsoft Excel 365, or .pdf format, in the response: Submit the response by email to the Primary Point of Contact and, if specified, to the Secondary Point of Contact listed in this notice as soon as possible, and preferably before the closing date and time of this notice. Please note that to be considered for award under any official solicitation, the entity must be registered and “active” in SAM at the time of solicitation response.
QUESTIONS REGARDING THIS NOTICE
Questions regarding this notice may be submitted via email to the Primary Point of Contact Junee Johnson junee.johnson@nist.gov listed in this notice. Questions should be submitted so that they are received 5 days prior to the response date. If the Contracting Officer determines that providing a written amendment to this notice to document question(s) received would benefit other potential respondents, the questions would be anonymized, and a written response to such question(s) would be provided via an amendment to this notice.
IMPORTANT NOTES
This notice is for market research purposes and should not be construed as a commitment by NIST to issue a solicitation or ultimately award a contract. There is no solicitation available at this time.
This notice does not obligate the Government to award a contract or otherwise pay for the information provided in response.
NIST reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate.
Any organization responding to this notice should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization’s capability.
Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted.
After a review of the responses received, a synopsis and solicitation may be published on GSA’s eBuy or SAM.gov. However, responses to this notice will not be considered an adequate response to any such solicitation(s).
Thank you for taking the time to submit a response to this request
COINCIDENT GAMMA RAY DETECTION SYSTEM, HIGH PURITY GERMANIUM DETECTOR, is a federal acquisition solicitation issued by DEPARTMENT OF COMMERCE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.