Active Solicitation · DEPT OF DEFENSE

    Enhanced Vyleater Vial Disposal System Model II-Xe

    Sol. PANHCA-26-029301Special NoticeSet-aside: No Set aside usedJBSA FT SAM HOUSTON, TX
    Open · 6d remaining
    DAYS TO CLOSE
    6
    closes Jun 9, 2026
    POSTED
    Jun 2, 2026
    Publication date
    NAICS CODE
    339112
    Primary industry classification
    PSC CODE
    6530
    Product & service classification

    AI Summary

    The Department of Defense is seeking a proposal for the Enhanced Vyleater Vial Disposal System Model II-Xe, designed to safely dispose of cytology thin prep vials. The system must be explosion resistant, self-contained, and comply with hazardous waste guidelines. It should accommodate approximately 300 vials per day and include training for technicians. Regional support and easy maintenance are also required.

    Contract details

    Solicitation No.
    PANHCA-26-029301
    Notice Type
    Special Notice
    Set-Aside
    No Set aside used
    Posted Date
    June 2, 2026
    Response Deadline
    June 9, 2026
    NAICS Code
    339112AI guide
    PSC / Class Code
    6530
    Contract Code
    2100
    Issuing Office
    W40M MRC0 WEST
    Primary Contact
    Derrick J Johnson
    State
    TX
    ZIP Code
    78234-4504
    AI Product/Service
    product

    Description

    Enhanced Vyleater Vial Disposal System Model II-Xe. DPALS process about 3,000 cytology thin prep vials per month that need to be disposed of in a safe and efficient manner. The device must be able to accommodate vials in their whole form. The device must be explosion resistant to substances with a flash point of 27 °C / 81 °F. The devise should separate solid waste materials in a separate container from the liquid waste. The device should be self-contained. The disposal system must comply with hazard waste guidelines. The device should not alter the waste material. The device should come with training for all technicians that will be required to utilize it. The device should be able to withstand mild exposure to environmental elements. The device needs to accommodate approximately 300 vials being disposed of per day, with each vial holding approximately 20ml of methanol-based solution. The regional technical support and service from manufacturer should be available in case the parts need to be ordered to repair. The operators training support should be available as requested. The device should be simple and easy to use for non-experienced operators. The device should be durable and easy to clean.

    Key dates

    1. June 2, 2026Posted Date
    2. June 9, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    Enhanced Vyleater Vial Disposal System Model II-Xe is a federal acquisition solicitation issued by DEPT OF DEFENSE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.