Closed Solicitation · DEPT OF DEFENSE
AI Summary
The Department of the Air Force is seeking information on a Ground Power Unit (GPU) capable of supporting aircraft start-up operations. The GPU must meet specific electrical and environmental specifications. Interested parties should submit their commercial solutions to the designated contacts via email.
DESCIPTION: THIS NOTICE IS A REQUEDT FOR INFORMATION ONLY. The RFI is issued solely for information and planning purposes – it does not constitute as a Request for Quote (RFQ) or a promise to issue an RFQ in the future. This RFI does not commit the Government to contact for any supply or service whatsoever. Responses will be treated as information only and will not be evaluated as a proposal. Further, the Government is not at this time seeking quotes and will not accept unsolicited quotes. A return response from the government regarding RFI submissions is not guaranteed. The RFI respondents are advised that the Government will not pay for any information or administrative costs incurred in response to this RFI; all costs associated with responding to this RFI will be solely at the interested party’s expense. Not responding to this RFI does not preclude participation from future announcements or contracts. Respondents should indicate which portions of their response are propriety and should mark accordingly.
NOTE: This RFI is not associated with any previous or ongoing RFQs or Fair Opportunity Proposal Requests issued by the DAF.
BACKGROUND: The 420th Instrumentation Group has a requirement for a Ground Power Unit (GPU) capable of supporting aircraft start-up operations.
GPU needs to have the capability of producing at least these specifications:
-600 Amps at 28VDC
-adjustable output voltage of 24 - 31.9 VDC
Input
• Voltage range:
3 x 400 V -10/+15%
3 x 460 V -10/+20%
• Frequency: 50/60 Hz 5%
• Rectification: 6 pulse
• Line current: 29 A
• Power factor: 0.91
• Inrush current: None, soft start
Output
• Current: 600 A continuously
(can be limited to 400 A upon
request)
• Engine Start Capability:
28 V @ 2000A
• Voltage: 28 VDC (or as adjusted - "24 - 31.9VDC"
• Ripple: less than 2% at full load
• Voltage regulation:
<0.5% from no load to full load
• Voltage compensation:
3 V @ 600 A
Manual or voltage feed-back
via interlock
Weight
• Fixed unit approx.
120 kg (264 lbs.)
• Mobile unit approx.
240 kg (582 lbs.)
Efficiency
• Overall efficiency: 0.87
• Stand by losses: 130W
• No load losses: 330W
Environmental
• Operating temperature:
-40°C to +56°C (-40°F to +135°F)
• Relative humidity 10-100%
non condensing
• Noise level <65 dB(A)@1m
Overload ratings
600 A 400 A
• 1200 A 800 A for 30 seconds
• 1800 A 1200 A for 10 seconds
• 2100 A 1400 A for 5 seconds
• 2400 A 1600 A for 2 seconds
Miscellaneous
• MTBF (proven): 100,000 hours
• Ventilation system: min. 25,000
hours
• MTTR: max. 20 minutes
• Communication: TCP/IP, USB
-mounted on a towable trailer that will raise the power supply and cables 18 off the ground for safety reasons.
All responses should include your commercial solution and be directed to the point of contact Jaymi Taplin, jaymi.taplin@us.af.mil, and Christina Day, christina.day.6@us.af.mil via email.