Closed Solicitation · DEPARTMENT OF HEALTH AND HUMAN SERVICES

    Hearing Aid Manufacturer

    Sol. IHSOKC2026-01Sources SoughtSet-aside: Indian Economic Enterprise (IEE) Set-Aside (specific to Department of Interior and Indian Health Services)OKLAHOMA CITY, OK
    Closed
    STATUS
    Closed
    closed Dec 17, 2025
    POSTED
    Dec 3, 2025
    Publication date
    NAICS CODE
    334510
    Primary industry classification
    PSC CODE
    6515
    Product & service classification

    AI Summary

    The Department of Health and Human Services is seeking manufacturers of programmable hearing aids with specific features for the dual sensory population. The opportunity emphasizes the need for actual manufacturers, not resellers, and outlines detailed technical requirements for the hearing aids. Interested parties should ensure compliance with the outlined specifications.

    Contract details

    Solicitation No.
    IHSOKC2026-01
    Notice Type
    Sources Sought
    Set-Aside
    Indian Economic Enterprise (IEE) Set-Aside (specific to Department of Interior and Indian Health Services)
    Posted Date
    December 3, 2025
    Response Deadline
    December 17, 2025
    NAICS Code
    334510AI guide
    PSC / Class Code
    6515
    Contract Code
    7527
    Primary Contact
    Edson Yellowfish
    State
    OK
    ZIP Code
    73114
    AI Product/Service
    product

    Description

    THE GOVERNMENT IS NOT LOOKING FOR A RESELLER OR PASS THROUGH, RATHER ACTUAL MANUFACTURES. All hearing aids shall be fully programmable. Minimum shade/color availability shall be: Dark brown, medium brown, and beige/light skin tone colors Highly Contrasting colors (for example: black and white, black/light grey) for a matching set of hearing aids for use with the dual sensory population. Sixteen (16) or more channels Three or more programs Adaptive directional microphone technology, unless not technologically feasible due to the size of the instrument Adaptive signal processing. Noise reduction strategies for steady state and transient noise. Wireless programmability, unless not technologically feasible due to the size of the instrument Programs accessible by the user. Active feedback suppression. Data logging. Wireless communication between hearing aids, of a binaural set, unless not technologically feasible due to the size of the instrument Average total harmonic distortion (THD) calculated by averaging the values measured at 500 Hz, 800 Hz, and 1600 Hz according to the procedures specified in American National Standards Institute (ANSI) Acoustical Society of America (ASA) S3.22-2014 shall be less than 5%. Equivalent input noise level measured according to the procedures specified in ANSI/ASA S3.22-2014 shall not exceed 29 dB. For power and super-power instruments, the equivalent input noise level measured according to these procedures shall not exceed 32 dB. Contractors shall have a range of hearing aids in each group appropriate for mild, moderate, and severe hearing losses. See definition list for definitions of mild, moderate, and severe. Contractors shall have a minimum of one (1) model in each group which has a matrix at or above an MPO of 125 dB SPL and maximum gain of 60 dB SPL.

    Key dates

    1. December 3, 2025Posted Date
    2. December 17, 2025Proposals / Responses Due

    AI search tags

    Frequently asked questions

    Hearing Aid Manufacturer is a federal acquisition solicitation issued by DEPARTMENT OF HEALTH AND HUMAN SERVICES. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.