Active Solicitation · DEPARTMENT OF VETERANS AFFAIRS

    J063--Building 350 Avigilon Security

    DEPARTMENT OF VETERANS AFFAIRS
    Sol. 36C25026Q0672SolicitationDAYTON, OH
    Open · 11d remaining
    DAYS TO CLOSE
    11
    closes Jul 24, 2026
    POSTED
    Jul 8, 2026
    Publication date
    NAICS CODE
    811210
    Primary industry classification
    PSC CODE
    J063
    Product & service classification

    AI Summary

    The Department of Veterans Affairs is soliciting proposals for the installation of Avigilon security systems in Building 350. The project includes access control for 12 doors, utilizing existing hardware and cabling. Specific equipment requirements include Mercury controllers and a Lantronix network switch. Bidders should ensure compatibility with existing systems.

    Contract details

    Solicitation No.
    36C25026Q0672
    Notice Type
    Solicitation
    Posted Date
    July 8, 2026
    Response Deadline
    July 24, 2026
    NAICS Code
    811210AI guide
    PSC / Class Code
    J063
    Contract Code
    3600
    Primary Contact
    Stacie I Hill
    City
    DAYTON
    State
    OH
    ZIP Code
    45428
    AI Product/Service
    service

    Award information

    Awardee
    null
    Award Date

    Description

    Q&A Can you please identify the 16 access-controlled doors included in the project scope? (1) 101A, (2) 147D & 112, (2) 122C & 132D, (1) 103B, (2) 108 & 119, (1) 128A, (2) 138A & 147E, (1) 115A. There are only 12 access controlled doors. Are the existing card readers, locks, REX devices, door contacts, and cabling intended to be reused? Yes Can you please identify the location of Room 138A on the Building 350 floor plan? On the blueprint, it is the unmarked room next to 138B Are there specific Avigilon controller models or part numbers required for this project? (1) Mercury MP1502, (1) Mercury MR-52-S3B Are there any specific requirements for the new network switch, including manufacturer, model, uplink, or fiber/SFP requirements? (1) 24 Port Network Switch Lantronix SM24TAT2S4 Are there any Drawings? Please see previous amendment. Are all existing Doors Hardware working? (Strikes, Mags, Card readers, Door contacts, Motions, Etc.) Yes Are we replacing any Hardware? (Strikes, Mags, Card readers, Door contacts, Motions, Etc.) No If existing Hardware Is not compatible/nonfunctional will that be covered under a Change order? All existing hardware should be compatible. Is all Existing Cabling working and compatible with Avigilon Access control? Yes Are we replacing Cabling? No How many Existing doors are in each one of these Existing Honeywell/C-Cure panels? (12) Door and (15) Readers Are we Wiring the Enclosures/Panels or just replacing Enclosures/Panels? Replacing Enclosures Life Safety Power (2) FPO 150-B100C808PE4M or (4) FPO 75-B100C4D8PE2M and wiring the enclosers What type of Media converters are Existing? Fiber to Ethernet How many Cat6/Fiber Ports do they need on their New Switch? 1 of each, 24 port switch for possible camera upgrade

    Key dates

    1. July 8, 2026Posted Date
    2. July 24, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    J063--Building 350 Avigilon Security is a federal contract award from DEPARTMENT OF VETERANS AFFAIRS. Review the award details including the awardee, contract value, and NAICS code.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.