Closed Solicitation · DEPT OF DEFENSE

    LCMS

    Sol. W911S226U2446Combined Synopsis/SolicitationSet-aside: Total Small Business Set-Aside (FAR 19.5)FORT DRUM, NY
    Closed
    STATUS
    Closed
    closed Jan 30, 2026
    POSTED
    Jan 14, 2026
    Publication date
    NAICS CODE
    334516
    Primary industry classification
    PSC CODE
    6630
    Product & service classification

    AI Summary

    The Department of the Army requires a combined liquid chromatography and mass spectrometer system. The instrument must support qualitative and quantitative analysis, include integrated software, and meet specific performance criteria. Delivery and installation are required at West Point, NY, with a one-year warranty included. This opportunity is classified under NAICS code 334516.

    Contract details

    Solicitation No.
    W911S226U2446
    Notice Type
    Combined Synopsis/Solicitation
    Set-Aside
    Total Small Business Set-Aside (FAR 19.5)
    Posted Date
    January 14, 2026
    Response Deadline
    January 30, 2026
    NAICS Code
    334516AI guide
    PSC / Class Code
    6630
    Issuing Office
    W6QM MICC-FT DRUM
    Primary Contact
    Carl Lundell
    State
    NY
    ZIP Code
    13602-5220
    AI Product/Service
    product

    Description

    Require an instrument that contains both liquid chromatography and mass spectrometer in paired/joined configuration. The preferred system for the liquid chromatograph and the mass spectrometer should have all items manufactured and serviced by the same company. The integrated software package should be able to operate and control both the mass spectrometer and liquid chromatograph instruments from a single unified operating platform. The system should be capable of performing both qualitative and quantitative analysis on a sample in a single run. Instrument must include all software to process quantification data and acquire samples, automatically restarts upon power failure and detect asymmetry in peak shape for quality assurance/quality control. The instrument must use a dual ion source that can provide both electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to the same sample. Desolvation capillary must be removeable and replaced without breaking vacuum which allows for easier maintenance. The detector must use an off axis, high energy conversion dynode coupled with a discrete multistage active film electron multiplier, without phosphorconversion. Maximum nitrogen consumption needs to be 15 L/min or less for nebulization and drying purposes. Autotuning function must be included that optimizes both positive and negative ion modes, all scan speeds, mass axis calibration, sensitivity, and mass resolution automatically with a single tuning solution. Must include a system check to provide essential information on the status of the instrument and can be integrated into batches for smooth maintenance and troubleshooting. Scan speed needs to be 15,000 u/sec in 0.1u steps without reducing scan mass range. Scan step resolution should be 0.7u at all scan speeds. Mass range must be from 2-2000 m/z to enable analysis of a wide range of analytes including large peptides with multi-charge states.Must include delivery and installation to West Point NY, 10996 and include a 1-year warranty on parts and labor.

    Key dates

    1. January 14, 2026Posted Date
    2. January 30, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    LCMS is a federal acquisition solicitation issued by DEPT OF DEFENSE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.