Closed Solicitation · DEPARTMENT OF COMMERCE

    NOTICE OF INTENT TO SOLE SOURCE FOR MICROWAVE DIGITAL LOCK-IN AMPLIFIER

    Special NoticeGAITHERSBURG, MD
    Closed
    STATUS
    Closed
    closed Jun 5, 2025
    POSTED
    May 22, 2025
    Publication date
    NAICS CODE
    334516
    Primary industry classification
    PSC CODE
    6640
    Product & service classification

    AI Summary

    The Department of Commerce's National Institute of Standards and Technology (NIST) intends to noncompetitively acquire a microwave digital lock-in amplifier, as outlined in FAR 13.106-1(b). This specialized equipment is essential for measuring photonic test structures and must meet specific technical requirements, including a frequency range of at least 1.8 GHz and multiple independent lock-in channels. This notice is not a request for quotations, and no solicitation will be issued.

    Contract details

    Notice Type
    Special Notice
    Posted Date
    May 22, 2025
    Response Deadline
    June 5, 2025
    NAICS Code
    334516AI guide
    PSC / Class Code
    6640
    Issuing Office
    DEPT OF COMMERCE NIST
    Primary Contact
    Nina Lin
    State
    MD
    ZIP Code
    20899
    AI Product/Service
    product

    Description

    Notice of Intent to Noncompetitively acquire a microwave digital lock-in amplifier.

    This notice is not a request for a quotation. A solicitation document will not be issued, and quotations will not be requested.

    This acquisition is being conducted under the authority of FAR 13.106-1(b). The North American Industry Classification System (NAICS) code for this acquisition is 334516– Analytical Laboratory Instrument Manufacturing a small business size standard of 1,000 employees.

    The National Institute of Standards and Technology (NIST) Photonics and Optomechanics Group within the Physical Measurement Laboratory in Gaithersburg, Maryland has a requirement for a digital lock-in amplifier for the measurement of photonic test structures that are being developed for characterization of integrated photonic fabrication processes and materials, among several other application. To measure the structure-, fabrication process- and material-dependent information contained in the high frequency responses of these test structures to optical and electrical stimuli, the system must be able to operate at frequencies of at least 1.8 GHz, and be capable of measuring the amplitude and phase of signals at multiple such frequencies and their harmonics simultaneously.

    The Contractor shall provide a digital lock-in amplifier that meets all technical specifications and performance specifications identified below:

    1. Number of independent lock-in channels: 2
    2. Frequency range: DC to 1.8 GHz or greater
    3. Lock-in input maximum analog-to-digital conversion (ADC) rate: ≥ 4 GSa/s
    4. Lock-in input ADC resolution: ≥ 14-bit
    5. Lock-in input voltage range: ≤ 10 mV to ≥ 1 V
    6. Lock-in input voltage noise: ≤ 6 nV/rt-Hz
    7. Dynamic reserve: ≥ 100 dB
    8. Output signal frequency range: DC to 1.8 GHz or greater
    9. Output signal maximum digital-to-analog conversion (DAC) rate: ≥ 6 GSa/s
    10. Output signal DAC resolution: ≥ 14-bit
    11. Output signal voltage range: ≤ 10 mV to ≥ 0.5 V
    12. Input and output signal connectors: Lock-in input connector: SMA or 2.92 mm, 50 ohm
    13. Number of dual-phase demodulators: ≥ 8
    14. Demodulator filter slope: selectable from ≤ 5 mHz to ≥ 10 MHz
    15. Demodulator filter slope: selectable from 6 to 48 db/octave
    16. Frequency reference resolution: 50 microHz
    17. Auxiliary signals: 4 output channels, 2 input channels
    18. Auxiliary output channel specification: ≥ 14 bit, ≥ 50 MSa/s
    19. Auxiliary input channel specification: ≥ 14 bit, ≥ 4 GSa/s
    20. Internal clock short term stability: ≤ 0.05 ppm deviation
    21. Internal clock aging: ≤ 0.3 ppm/year
    22. Software: Run using Zurich Instruments LabOne software platform for interoperability with existing lock-in instruments running using this platform.
    23. Computer interface: USB 3.0 and Gigabit Ethernet
    24. Line power: 120 V AC, 60 Hz
    25. At least 6 additional frequencies for synchronous lock-in measurements, and amplitude and frequency modulation analysis with same specifications as the base.
    26. Number of independent PID channels: ≥ 4
    27. Maximum PID bandwidth: ≥ 1 MHz
    28. Input parameters: X, Y, R and Theta outputs of lock-in amplifier and auxiliary inputs
    29. Two independent AM/FM (amplitude/frequency) modulation units with 3 frequency components each
    30. Simultaneous sideband modulation and demodulation
    31. Harmonic sideband analysis

    NIST conducted market research in March to April 2025 to determine what sources could potentially meet NIST’s minimum requirements. This included searches on GSA; SAM; Thomas Register; surveying vendor websites; speaking with subject matter experts inside and outside of NIST; and issuance of a Sources Sought Notice on SAM.gov. The results of market research revealed that only Zurich Instruments AG (UEI: WXNAU91NVWB6) appears to be capable of meeting NIST’s requirements.

    However, any sources that believe they are capable of meeting NIST’s minimum requirements are encouraged to respond to this notice by the response date to provide the following information at a minimum: Company Unique Entity Identifier (UEI) number in https://sam.gov; details about what your company is capable of providing that meets or exceeds NIST’s minimum requirements; whether your company is an authorized reseller of the product or service being cited and evidence of such authorization; and any other information that can help NIST determine whether this requirement may be competitively satisfied. 

    A determination by the Government not to compete the proposed acquisition based upon responses to this notice is solely within the discretion of the Government. Information received will be considered solely for the purpose of determining whether to conduct a competitive procurement. Only responses received by the offers due date and time of this notice will be considered by the government. Responses shall be submitted via email to nina.lin@nist.gov.

    Key dates

    1. May 22, 2025Posted Date
    2. June 5, 2025Proposals / Responses Due

    AI search tags

    Frequently asked questions

    NOTICE OF INTENT TO SOLE SOURCE FOR MICROWAVE DIGITAL LOCK-IN AMPLIFIER is a federal acquisition solicitation issued by DEPARTMENT OF COMMERCE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.