Active Solicitation · DEPT OF DEFENSE

    Plate Reader

    Sol. W911S226U3818Combined Synopsis/SolicitationFORT DRUM, NY
    Open · 1d remaining
    DAYS TO CLOSE
    1
    closes Aug 6, 2026
    POSTED
    Jul 24, 2026
    Publication date
    NAICS CODE
    334516
    Primary industry classification
    PSC CODE
    6630
    Product & service classification

    AI Summary

    The Department of Defense is seeking a plate reader capable of real-time data acquisition across multiple measurement modes, including fluorescence and UV/Vis absorbance. Key features include a linear variable monochromator, heated optics, and automated injection systems. The instrument must also include software for data visualization and analysis. This opportunity is classified under NAICS code 334516.

    Contract details

    Solicitation No.
    W911S226U3818
    Notice Type
    Combined Synopsis/Solicitation
    Posted Date
    July 24, 2026
    Response Deadline
    August 6, 2026
    NAICS Code
    334516AI guide
    PSC / Class Code
    6630
    Contract Code
    2100
    Issuing Office
    W6QM MICC-FT DRUM
    Primary Contact
    Carl Lundell
    State
    NY
    ZIP Code
    13602-5220
    AI Product/Service
    product

    Description

    We require an instrument that can acquire real-time data from multiple modes of measurement, including monochromator-based fluorescence, UV/Vis absorbance, and luminescence. We require the following: linear Variable Monochromator, permitting tunable band passes up to 100nm; a tunable dichroic mirror permitting air-based light path for monochromator without light guides or fiberoptics; auto ranging of detector sensitivity and gain for fluorescence measurements below 760,000,000-counts; enhanced Dynamic Range autoranging of detector sensitivity in less than 0.1s; absorbance based on a dedicated spectrometer, not a monochromator. Complete UV/Vis absorbance spectrum from 220nm-1000nm at 1nm resolution in less than 0.5s with all wavelengths captured simultaneously with a diode array; heated optics. A heated optical head means that incubated microplate wells remain in a uniform temperature environment even during detection. The instrument should have a temperature controller than can go up to 45 ?C, bottom reading, two reagent injectors for automated injection for initiating kinetic events and flash luminescence, and an atmospheric control unit with software-controlled CO2 andO2 concentrations for cell culture at 5% CO2. The unit should come with software for data visualization and analysis.

    Key dates

    1. July 24, 2026Posted Date
    2. August 6, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    Plate Reader is a federal acquisition solicitation issued by DEPT OF DEFENSE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.