Closed Solicitation · DEPT OF DEFENSE

    Repair and Calibration of VigilOX Inhalation Sensor Block (ISB) models ISB001 and ISB003

    Sol. F1S0AM6071A001PresolicitationSet-aside: No Set aside usedEDWARDS AFB, CA
    Closed
    STATUS
    Closed
    closed Mar 31, 2026
    POSTED
    Mar 31, 2026
    Publication date
    NAICS CODE
    811210
    Primary industry classification
    PSC CODE
    J066
    Product & service classification

    AI Summary

    The U.S. Air Force intends to issue a sole source contract for the repair and calibration of VigilOX Inhalation Sensor Block models ISB001 and ISB003. Mission Systems Orchard Park Inc is the only vendor capable of providing these specialized services, ensuring compliance with safety standards and maintaining the precision required for pilot breathing systems.

    Contract details

    Solicitation No.
    F1S0AM6071A001
    Notice Type
    Presolicitation
    Set-Aside
    No Set aside used
    Posted Date
    March 31, 2026
    Response Deadline
    March 31, 2026
    NAICS Code
    811210AI guide
    PSC / Class Code
    J066
    Contract Code
    5700
    Issuing Office
    FA9302 AFTC PZZ
    Primary Contact
    Jenna Jacobson
    State
    CA
    ZIP Code
    93524-1185
    AI Product/Service
    service

    Description

    Notice Type: Presolicitation Notice Anticipated Contract Award Date: 15 April 2026 Contract Award Number: TBD This is a Sole Source presolicitation notice. No small business set-asides apply. NAICS Code: 811210 FSC/PCS: J066 Description: The United States Air Force Test Center/Directorate of Contracting (AFTC/PZZG), located at 5 S. Wolfe Ave, Edwards AFB, CA, 93524 intends to issue a sole source, FFP contract to a large business, Mission Systems Orchard Park Inc (CAGE: 04577) located at 10 Cobham Dr. Orchard Park, New York 14127-4121, for repair and calibration of the VigilOX Inhalation Sensor Block (ISB) models ISB001 and ISB003, P/N B63089-1. The contract will be executed by means of other than full and open competition, due to Mission Systems Orchard Park Inc being the manufacturer and sole entity capable of calibrating and repairing these items. Justification, Statutory Authority: Per RFO 6.103 Other than full and open competition. (a) Agencies may contract without providing for full and open competition under authorities specified in this section (see 10 U.S.C. 3204 and 41 U.S.C. 3304). RFO 6.103-1 Only one responsible source and no other supplies or services will satisfy agency requirements. The authority permitting the use of noncompetitive procedures is 10 U.S.C. 3204(a)(1) or 41 U.S.C. 3304(a)(1). In order to comply with RFO 5.101(c)(4)(vii), the reason for lack of competition is as follows: Eaton Corporation (a parent company of Mission Systems Orchard Park Inc) is a global power management company that builds VigilOX pilot breathing sensors and ISBs; and is the only vendor capable of servicing the VigilOX ISB. The VigilOX Inhalation Sensor Block (ISB) models ISB001 and ISB003 are highly specialized components used in pilot breathing systems, designed to measure physiological data such as oxygen flow rates, concentrations, pressure, and temperature at the point of inhalation. The manufacturer, Mission Systems Orchard Park Inc, requires these sensors to be calibrated and repaired in-house to ensure high precision and regulatory compliance for life-support technology. Proprietary Calibration Technology: The manufacturer develops proprietary calibration solutions that verify not just single points, but ensure all values are within strict specifications. Regulatory Compliance (FDA/ISO): As devices designed for pilot breathing, these sensors are subject to rigorous safety standards. Under guidelines similar to 21 CFR Part 820, manufacturers must ensure traceability to national or international standards (such as NIST), which is best achieved through authorized manufacturer service. Sensor Complexity and Precision: The ISB001/ISB003 sensors are specialized for environmental data capture during flight. Accurate calibration requires specialized knowledge of how pressure, temperature, and specific gas mixtures (like 100%) impact the sensor readings. Warranty and Liability Risk: Utilizing third-party or non-OEM services can void manufacturer warranties and leaves the equipment non-compliant, posing significant liabilities, particularly in safety-critical applications like aviation. Full System Maintenance: Manufacturer service often includes cleaning the internal components, applying firmware updates, and repairing wearable housing parts to prevent malfunctions, such as overheating or short circuits, which a general service provider may not cover. While some oxygen sensors can be calibrated in the field, complex systems that require high precision under specific environmental conditions, such as cabin pressure and varying oxygen concentrations, are generally limited to factory service to ensure reliability. Therefore, Mission Systems Orchard Park Inc is the only vendor who can calibrate and repair these items. FAR 52.225-3, Buy American–Free Trade Agreements–Israeli Trade Act, FAR 52.225-5, Trade Agreements, and FAR 52.225-11, Buy American-Construction Materials under Trade Agreements, or FAR 52.225-23, Required Use of American Iron, Steel, and Manufactured Goods-Buy American Statute-Construction Materials under Trade Agreements do not apply to this acquisition. There are no solicitation documents; however, any vendors that believe they can meet the requirements described should submit a complete technical package, which provides clear and convincing evidence that they can meet the Government’s requirement. Contractors must be registered in System for Award (SAM) at www.sam.gov Please submit all questions, comments, and feedback regarding this product to the following Points of Contact: ? Ms. Carmen Barahona, Contract Specialist, Email: carmen.barahona@us.af.mil ? Ms. Jenna Jacobson, Contracting Officer, Email: jenna.jacobson@us.af.mil No telephone responses will be accepted. Any information submitted by respondents to this Notice of Contract Action is strictly voluntary. To the maximum extent possible, please submit non-proprietary information. Any proprietary information submitted should be identified as such and will be properly protected from disclosure. No classified information shall be submitted. Any response submitted by respondents to this Notice of Contract Action constitutes consent for that submission to be reviewed by Government personnel. The Air Force Test Center has appointed an Ombudsman to consider and facilitate the resolution of concerns from offerors, potential offerors, and others for this acquisition. Concerned parties should address their concerns, issues, disagreements, and/or recommendations to the Contracting Officer for resolution prior to consulting the Ombudsman. Additionally, Air Force Federal Acquisition Regulation (AFFARS) 5352.201-9101 – Ombudsman, will be included in any potential solicitation and contract for this acquisition. The AFTC Ombudsman contact information is as follows: Air Force Test Center Vice Commander 1 South Rosamond Blvd, Edwards AFB, CA 93524-3784. Phone Number (661) 277-2810, Facsimile Number (661) 277-7593, Email: aftc.workflow@us.af.mil. DISCLAIMER AND NOTICE: This is a presolicitation notice only and does not constitute a commitment, implied or otherwise, that AFTC/PZZG, will take procurement action on this matter. This is NOT a request for proposals, applications, proposal abstracts, or quotation. This courtesy Notice of Contract Action only shall not be construed as an obligation on the part of the Government. Further, the Government will NOT be responsible nor reimburse any submitters of information for any cost incurred in furnishing this information. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. Any organization responding to this notice should ensure that its response is complete and sufficiently detailed. Information provided will be used to assess tradeoffs and alternatives available for the potential requirement. Respondents are advised that the Government is under no obligation to provide feedback to respondents with respect to any information submitted.

    Key dates

    1. March 31, 2026Posted Date
    2. March 31, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    Repair and Calibration of VigilOX Inhalation Sensor Block (ISB) models ISB001 and ISB003 is a federal acquisition solicitation issued by DEPT OF DEFENSE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.