    The Department of Veterans Affairs is seeking sources for a minimum of three VPRO MAX2 low temperature sterilizers. These sterilizers must meet specific dimensions and operational requirements, including vaporized hydrogen peroxide sterilization processes suitable for heat-sensitive materials. Interested vendors should ensure compliance with ANSI/AAMI standards and provide necessary utility requirements.

    Contract details

    Solicitation No.
    36C25526Q0154
    Notice Type
    Sources Sought
    Posted Date
    January 14, 2026
    Response Deadline
    January 21, 2026
    NAICS Code
    334510AI guide
    PSC / Class Code
    6515
    Primary Contact
    Jon Lutmer
    State
    KS
    ZIP Code
    66048
    AI Product/Service
    product

    Description

    2. SPECIFICATIONS
    . Minimum of three low temperature sterilizers shall have a minimum individual dimensions of
    Cabinet (DD): 33 x 40-15/16 x 72” (838 x 1040 x 1829 mm) with Recessed/Cabinet (SD): 33 x 38-
    5/16 x 72” (838 x 973 x 1829 mm).
    o Mounting single door, cabinet
    o System installation requires no plumbing, ventilation or air
    o supply – only a dedicated electrical connection is needed. A power cord is supplied for
    this connection
    o The facility space in which the vehicle can occupy is approx. 35’ x 110’.
    . Vaporized hydrogen peroxide sterilization processes are particularly suited for sterilizing heatsensitive
    materials because temperatures within the load currently do not exceed 55ºC (131ºF)
    and sterilization occurs in a low-moisture environment. Heat tolerant devices and materials can
    also be indicated for vaporized hydrogen peroxide sterilization processes. FDA-cleared vaporized
    hydrogen peroxide sterilizers, either with or without plasma, are currently available in the
    United States.
    . Per ANSI/AAMI ST58:2013 or subsequent, the sterilizer shall be installed and operated in an area
    with a ventilation system capable of at least 10 air exchanges per hour.
    . VPRO MaX2 must support utility requirements:
    o Current 16 AMP
    o Minimum Circuit Breaker 20 AMPS
    o Use NEMA L15-20R Plug
    o Provide grouped or ganged circuit protection and disconnect for phase 3 power as
    required by NEC and local codes.
    o Individual power shutoffs near each machine for servicing.

    Key dates

    1. January 14, 2026Posted Date
    2. January 21, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    VPRO MAX2 LOW TEMP STERILIZERS is a federal acquisition solicitation issued by DEPARTMENT OF VETERANS AFFAIRS. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.