Closed Solicitation · DEPARTMENT OF ENERGY

    XY MANIPULATOR FLANGES

    DEPARTMENT OF ENERGY
    Sol. SLAC_365674_XYManipulatorFlangesSolicitationMenlo Park, CA
    Closed
    STATUS
    Closed
    closed May 29, 2026
    POSTED
    May 21, 2026
    Publication date
    NAICS CODE
    3333
    Primary industry classification
    PSC CODE
    AJ12
    Product & service classification

    AI Summary

    The SLAC National Accelerator Laboratory is soliciting quotes for XY manipulator flanges and related components. The opportunity is for product procurement only, with a focus on lowest price and best lead time. Quotes are due by May 28, 2026, and must comply with the Buy American Act. Interested suppliers should submit their proposals to the provided email.

    Contract details

    Solicitation No.
    SLAC_365674_XYManipulatorFlanges
    Notice Type
    Solicitation
    Posted Date
    May 21, 2026
    Response Deadline
    May 29, 2026
    NAICS Code
    3333AI guide
    PSC / Class Code
    AJ12
    Primary Contact
    Katherine Jill A. Coh
    State
    CA
    ZIP Code
    94025
    AI Product/Service
    product

    Description

    SLAC National Accelerator Laboratory is operated by Stanford University for the Department of Energy.  As a management and operating contractor, subcontracts awarded by the Laboratory are not Federal procurements, and are not directly subject to the Federal Acquisition Regulations in 48 CFR. Nonetheless, certain Federal laws, Executive Orders, and regulations may affect our DOE approved purchasing system, as required by statute, regulation, or contract terms and conditions.

    The following is attached for you to complete and review:

    2.) Reps & Certs

    3.) FP Commercial Supplies-Services T&C’s ( August  2023 )

    4.) Buy American Act (BAA)

    Requested for Quote:

    Technical Specifications listed below:

    TECHNICAL REQUIREMENTS FOR XY STAGE:

    UHV STAGE

    • XY Manipulator on 8" (CF150) flanges
      • +/-2.0" (50 mm) travel
    • 6.00" (150 mm) clear ID
    • Top flange tapped inch
    • Bottom flange tapped inch
    • Stepper drive with limit switches (4 wire motor, requires drive and controller)
    • Renishaw Asbsolute Encoders X and Y 9 pin D type plug, standard 2m cables LA11DCA13BKA20DAOO

    TECHNICAL REQUIREMENTS FOR Z STAGE:

    UHV STAGE

    • Z translator with 6 inch (CF100) traveling flange
    • 4.00 inch (10mm) clear ID
    • 8 inch (200mm) travel
    • 6.00 CF top flange, tapped inch
    • 6.00 CF Bottom Flange with clearance holes
    • Stepper motor drive, top (inline) mounted, with gear reducer, with limit switches (4 wire motor, requires drive and controller
    • Inch scale
    • Renishaw Asbsolute Encoder Z Axis 9 pin D type plug, standard 2m cable LA11DCA13BKA20DAOO

    TECHNICAL REQUIREMENTS FOR ROTATION STAGE:

    • Differentially-pumped Rotary Platform for 4.5" (CF63) flanges, with 2.87" (73 mm) clear ID and fine adjustment worm drive.
      • Top flange half nipple TAPPED Inch Align FLUSH with RESA Ring
      • Bottom flange tapped inch
      • Stepper motor drive (4-wire motor, requires drive and controller)
    • Renishaw RESOLUTE Absolute Optical Encoder RESA Ring- One Piece stainless ring, true absolute scale

    Required item(s) are listed below:

    XY Manipulator on 8" (CF150) flanges, top flange tilt

    Quantity:      1

    Z translator with 6 inch

    Quantity:      1

    Differentially-pumped Rotary Platform for 4.5".. Align FLUSH with RESA Ring

    Quantity:      1

    Quote is for product only; no on-site services permitted.

    Source selection will be based on Lowest Priced Method and best Lead-Time.

    Please provide a price and lead time quotation by 5/28/2026.

    Send quote to Jhamieb@SLAC.stanford.edu.

    Is there any room for additional discount such as for Academic, ICPT, GSA, or Government Institutions?

    Buy American Act Certification (BAA) applies to awards over $15,000 unit price.

    Representations & Certifications Rider is required. Once completed the Reps and Certs is valid for one year until renewal. If you have already completed one within the year please disregard. Otherwise, please complete and return.

    Please include in your proposals the Harmonized Tariff Schedule (HTS Code) if applicable.

    All subcontractors are required to register in the System for Award Management (www.sam.gov).

    If possible, please provide a link to your webpage for published price list to substantiate for the prices quoted.

    The resulting purchase order will be issued on a fixed price basis. SLAC National Accelerator Laboratory Terms and Conditions for Fixed Price Commercial Supplies and Services (Rev. August 2023) will be made a part of the resulting order. Please mark up terms and conditions if you wish to negotiate. No mark ups mean that you accept SLAC Terms and Conditions.

    Payment Terms will be NET-15 – SLAC is offering small businesses NET 15 - ___McAllister Technical Services Inc_____is considered a small business.

    Domestic Suppliers - Freight terms will be FOB Destination Prepaid and Add.

    Foregin Supplier - Shipment will be made CIP SLAC, Menlo Park, and Duty Unpaid.

    You are requested to mark and identify proprietary/confidential information provided in response to the solicitation.

    Contact me directly with any questions.

    Kind Regards,

    Jhamie Serena

    Procurement Commodities Team

    SLAC National Accelerator Laboratory

    2575 Sand Hill Road Menlo Park, CA 94025

    P- 650-926-2201

    Key dates

    1. May 21, 2026Posted Date
    2. May 29, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    XY MANIPULATOR FLANGES is a federal acquisition solicitation issued by DEPARTMENT OF ENERGY. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.