Active Solicitation · DEPARTMENT OF VETERANS AFFAIRS

    Z1DA--Repair Compressor for AHU 21 Chiller

    DEPARTMENT OF VETERANS AFFAIRS
    Sol. 36C24126Q0426Combined Synopsis/SolicitationSet-aside: Service-Disabled Veteran-Owned Small Business Set AsideTOGUS, ME
    Open · 6d remaining
    DAYS TO CLOSE
    6
    closes May 19, 2026
    POSTED
    May 5, 2026
    Publication date
    NAICS CODE
    811310
    Primary industry classification
    PSC CODE
    Z1DA
    Product & service classification

    AI Summary

    The Department of Veterans Affairs is seeking proposals for the repair of the compressor for AHU 21 Chiller at Togus VA Medical Center. A site visit is scheduled for May 14, 2026, and responses are due by May 19, 2026. The project involves specific requirements for refrigerant recovery and oil management during the replacement process.

    Contract details

    Solicitation No.
    36C24126Q0426
    Notice Type
    Combined Synopsis/Solicitation
    Set-Aside
    Service-Disabled Veteran-Owned Small Business Set Aside
    Posted Date
    May 5, 2026
    Response Deadline
    May 19, 2026
    NAICS Code
    811310AI guide
    PSC / Class Code
    Z1DA
    Contract Code
    3600
    Primary Contact
    Kenya R Mitchell
    City
    TOGUS
    State
    ME
    ZIP Code
    04330
    AI Product/Service
    service

    Award information

    Awardee
    null
    Award Date

    Description

    Combined Synopsis-Solicitation for Commercial Products and Commercial Services Effective Date: 04/18/2025 Revision: 02 THE PURPOSE OF THIS AMENDMENT IS TO: 1. Schedule site visit 14, May 2026 at 10:00 AM Togus VA Medical Center 1 VA Center Augusta, ME 04330 Building B200E POC: Abigail Campbell 2.Respond to question received: I am writing to request clarification regarding the compressor replacement for AHU 21 Chiller. Specifically, we would like to confirm whether the compressor can be isolated during the replacement process, or if the addition of new refrigerant will be required. Isolating the compressor during replacement is not possible. The refrigerant from the entire circuit must be recovered and, because of the nature of the failure, cannot be reused. Additionally, during installation, the oil equalizer line will need to be drained, and fresh oil should be added to the circuit to ensure proper system functionality 3. Extend the submission due date Submission of your response shall be received not later than Tuesday, 19 May 2026 by 5:00 PM EST. Late submissions shall be treated in accordance with the solicitation provision at FAR 52.212-1(f). Any questions or concerns regarding this solicitation should be forwarded in writing via e-mail to the Point of Contact listed below. Point of Contact Kenya.Mitchell1@va.gov

    Key dates

    1. May 5, 2026Posted Date
    2. May 19, 2026Proposals / Responses Due