SLED Opportunity · TEXAS · CITY OF EAGLE PASS
AI Summary
The City of Eagle Pass seeks qualified general contractors for the Patsy Winn Blvd Extension Project involving construction of 1.7 miles of roadway, sidewalks, drainage, and related infrastructure. Funded partly by the EDA, proposals will be evaluated for best value under Texas law.
The City of Eagle Pass (CITY) is soliciting Competitive Sealed Proposals (CSP) from qualified General Contractors (GC) for the City of Eagle Pass Patsy Winn Blvd Extension Project (RFP #2026-014). The scope of work generally consists of the construction of approximately 1.7 miles of roadway infrastructure extending Patsy Winn Boulevard and terminating at the City of Eagle Pass Sports Complex. The project includes, but is not limited to, the construction of two (2) 16-foot travel lanes, concrete curb and gutter, drainage improvements, and a four (4) foot sidewalk along the west side of the roadway, together with all associated grading, utilities, and roadway improvements as detailed in the project plans and specifications provided in Attachment A – Design Documents. This project is funded in part through the U.S. Economic Development Administration (EDA) under Award No. 08-79-05668. As such, the selected contractor must comply with all applicable federal, state, and local laws and regulations, including procurement and contracting requirements under 2 C.F.R. Part 200, EDA grant conditions, and all applicable Texas statutes governing public works construction. Proposals will be evaluated and ranked in accordance with the Competitive Sealed Proposal method authorized under Texas Government Code Chapter 2269. The CITY will select the Offeror whose proposal provides the best value to the City, considering the evaluation criteria and weighted values identified in this Request for Proposals, together with the results of the proposal evaluation and ranking process. The City reserves the right to conduct discussions with Offerors, request best and final offers if necessary, and negotiate with the highest-ranked proposer in accordance with applicable law prior to contract award. --- QUESTIONS AND ANSWERS --- Q: Are CAD files available? A: Please stay put to our Addendum. Q: Will you include a unit price bid form for this project?? A: Yes an addendum will be added to include Bid Form. Q: Can Ty B Gr 3 caliche base be used in lieu of A-2 base ? A: Consideration will be given to utilize Ty B Gr 3 caliche in lieu of A-2 given enough engineering design data is provided to justify the structural design of the alternative cross section Q: On the set of plans, more specifically the Culvert 3 Plan & Profile calls for the installation and procurement of 10' x 5' Box Culverts, I do not see this Line Item on the Bid Form. A: No answer provided yet. Q: Because of the possible long lead time for the Box Culverts, could you please include a detail for the cast-in place Culverts? Thank you A: No answer provided yet. Q: What is the total acreage that requires clearing and grubbing? A: No answer provided yet. Q: Is there an available detail for the rip-rap adjacent to wingwalls? A: No answer provided yet. Q: is there a detail for the connection between the top of the culverts and the top part of the Wingwalls? A: No answer provided yet. Q: is there a detail of the RCP (3:1) 18",24" and 36" for the alternate? A: No answer provided yet. Q: Where is alternate shown on the plans? A: No answer provided yet. Q: What lbs/sy is Hotmix figured at? A: No answer provided yet. Q: As per our Takeoff we show 75000 cut 50,000 fill. this is with pavement section of 19 inches base and 6 inches HMAC. Quantity on bid comes out very close when section is run to design. Can this be confirmed? A: No answer provided yet. Q: Page 25 of plan sheet has quantities on top right showing 484 CY of concrete flume which is only 6,000 SF +/-. Rest of drainage swells say earthen channel. Where is additional concrete rip rap going and can it be outlined on plans? A: No answer provided yet. Q: is there an specifications book available for bidding this project? A: No answer provided yet. Q: Geotech study available? A: No answer provided yet. Q: will light poles be included in this package? A: No answer provided yet. Q: Can a detail for the concrete flume be provided? A: No answer provided yet. Q: Culvert 7 is left off of the BCS sheet, can you please provide that information? A: No answer provided yet. Q: Wingwall PW 2 HW=10 shows on the estimate sheet to be at culvert 6, however, on the culvert 6 sheet, both HW=11'. Please clarify. A: No answer provided yet. Q: Can you provide a detail for the Concrete Driveway item? A: No answer provided yet. Q: Can you provide a detail for the curb & gutter item? A: No answer provided yet.
SLED stands for State, Local, and Education. These are solicitations issued by state governments, counties, cities, school districts, utilities, and higher education institutions — as opposed to federal agencies.
SamSearch Platform
AI-powered intelligence for the right opportunities, the right leads, and the right time.