    The Department of Defense is seeking proposals for a fire trainer liner designed for extreme live-fire training. The liner must meet safety and regulatory specifications, be made of a high-temperature composite, and include features such as Kevlar additives and a unique installation method. A warranty of five to ten years is required, along with compliance with NFPA standards.

    Contract details

    Solicitation No.
    FA480926Q0065
    Notice Type
    Presolicitation
    Set-Aside
    Total Small Business Set-Aside (FAR 19.5)
    Posted Date
    July 21, 2026
    Response Deadline
    July 30, 2026
    NAICS Code
    238990AI guide
    PSC / Class Code
    4240
    Contract Code
    5700
    Issuing Office
    FA4809 4TH CONS SQ CC
    Primary Contact
    Michael A. Berg
    State
    NC
    ZIP Code
    27531-2456
    AI Product/Service
    product

    Description

    SALIENT CHARACTERISTICS for Structural Trainer Liner DESCRIPTION: Replace liner inside the structural trainer REQUIREMENTS: The liner components units shall: 1. Designed to meet all referenced safety, thermal, and regulatory specifications, this specific material is engineered for extreme live-fire training evolutions. 2. Specifically formulated for Class A, B, C, D, Electrical, and F/K fires within a controlled burn cell which complies with NFPA 1402 and related standards. 3. Made of a cementitious high temp composite formula, which has a negative health impact when installed by certified installers. 4. Have Kevlar additives 5. Unique tongue and groove installation method 6. Stainless Steel mounting hardware 7. Have five (5) to ten (10) year warranty to replace 8. Able to withstand 150 psi nozzle forces 9. 1.5 inches thick requires no additional insulation behind its barrier 10. Heat transfer 10.4% (1000 degree / 140 degree in 10 minutes) 11. Complies with all NFPA suggested burn matrix formulas 12. Certified as a protective skin for flammable hazmat storage cells

    Key dates

    1. July 21, 2026Posted Date
    2. July 30, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    Fire Trainer Liner is a federal acquisition solicitation issued by DEPT OF DEFENSE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.