Closed Solicitation · DEPT OF DEFENSE

    HOLOGIC MAMMOGRAPHIC TECHNICIANS, SYSTEM MAINTENANCE, AND REPAIR AT MADIGAN ARMY MEDICAL CENTER

    Sol. PANDHA26P0000_042092Sources SoughtFALLS CHURCH, VA
    Closed
    STATUS
    Closed
    closed Aug 4, 2026
    POSTED
    Jul 28, 2026
    Publication date
    NAICS CODE
    811210
    Primary industry classification
    PSC CODE
    J065
    Product & service classification

    AI Summary

    The Defense Health Agency is seeking sources for maintenance and repair services of 3D Mammography systems at Madigan Army Medical Center. This opportunity requires contractors to provide certified technicians and all necessary resources to ensure equipment operates according to OEM standards. This is a sources sought notice, not a solicitation.

    Contract details

    Solicitation No.
    PANDHA26P0000_042092
    Notice Type
    Sources Sought
    Posted Date
    July 28, 2026
    Response Deadline
    August 4, 2026
    NAICS Code
    811210AI guide
    PSC / Class Code
    J065
    Issuing Office
    DEFENSE HEALTH AGENCY
    Primary Contact
    Wanda Williams
    State
    VA
    ZIP Code
    28547-0100
    AI Product/Service
    service

    Description

    Defense Health Agency is currently seeking sources for a possible upcoming contracting opportunity. This is not a solicitation for offers. We are only requesting contractors provide capabilities that could fulfill a possible future requirement. The possible requirement is for a capable contractor to  provide all-inclusive, nonpersonal services for the maintenance and repair of  3D Mammography systems and associated components. This includes providing all personnel, equipment, supplies, transportation, tools, materials, and supervision necessary. The objective is to ensure the equipment maintains optimum operation and conforms to Original Equipment Manufacturer (OEM) standard specifications. Services include periodic preventative maintenance, calibration, on-site emergency labor, comprehensive parts coverage, and installation of all OEM-sponsored modifications. The background for this requirement is the need to support the mission of the Military Healthcare System (MHS) at Madigan Army Medical Center, which utilizes this critical equipment to serve its beneficiaries.

    This requirement fulfill the possible requirement to provide Original Equipment Manufacturer (OEM) fully certified/qualified technicians to perform the maintenance and repair services for 3D Mammography system and components as described herein, to ensure that optimum operation and efficiency of the equipment is maintained, and that proper functioning of the equipment conforms to the OEM standard specifications. Contractor shall have knowledge of, furnish and install all OEM sponsored modifications at no additional charge. Additionally, the Contractor shall have access to all required OEM tools, technical repair or service manuals, software, firmware, and any other required parts or proprietary knowledge that would be reasonably necessary to perform through the life of this contract and all associated task orders. This includes all the OEM published Equipment Changed Orders (ECO) and Fielded Change Orders (FCO). Mandatory modifications include equipment upgrades or enhancements to equipment design and changes necessary for operator and patient safety. Services include 3D MAMMOGRAPHY SYSTEM Maintenance and Repair Service

    Key dates

    1. July 28, 2026Posted Date
    2. August 4, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    HOLOGIC MAMMOGRAPHIC TECHNICIANS, SYSTEM MAINTENANCE, AND REPAIR AT MADIGAN ARMY MEDICAL CENTER is a federal acquisition solicitation issued by DEPT OF DEFENSE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.