Closed Solicitation · DEPT OF DEFENSE

    JANUS LOW PRESSURE CARBON DIOXIDE REFRIGERATED STORAGE UNIT FOR CENTER HILL DAM

    Special NoticeNASHVILLE, TN
    Closed
    STATUS
    Closed
    closed Sep 15, 2025
    POSTED
    Sep 10, 2025
    Publication date
    NAICS CODE
    238990
    Primary industry classification
    PSC CODE
    5430
    Product & service classification

    AI Summary

    The U.S. Army Corps of Engineers Nashville District intends to award a sole source contract for the supply and delivery of a 4-ton Janus Low Pressure Carbon Dioxide Refrigerated Storage Unit. Interested parties may submit product information by September 15, 2025. This opportunity is not open for competitive quotes.

    Contract details

    Notice Type
    Special Notice
    Posted Date
    September 10, 2025
    Response Deadline
    September 15, 2025
    NAICS Code
    238990AI guide
    PSC / Class Code
    5430
    Issuing Office
    W072 ENDIST NASHVILLE
    Primary Contact
    Kenyanna Jennings
    State
    TN
    ZIP Code
    37203-1070
    AI Product/Service
    product

    Description

    THIS IS A NOTIFICATION OF INTENT TO AWARD A BRAND NAME SPECIFICATION IN A FUTURE CONTRACT FOR CENTER HILL DAM

    U.S. ARMY CORPS OF ENGINEERS – NASHVILLE DISTRICT’S NOTICE OF INTENT TO INCLUDE BRAND NAME SPECIFICATION IN A FUTURE CONTRACT FOR SUPPLY AND DELIVERY OF ONE (1) 4-TON JANUS LOW PRESSURE CARBON DIOXIDE REFRIGERATED STORAGE UNIT – SOLICITATION W912P525QA***

    The U.S. Army Corps of Engineers Nashville District will be soliciting a sole source quote for a Single Award Firm Fixed-Price supply contract to The Hiller Companies LLC for the supply and delivery of one (1) 4-Ton Janus Fire Systems® Low Pressure Carbon Dioxide Refrigerated Storage Unit. The Four-Ton Low Pressure Carbon Dioxide Storage Tank shall be designed to work within the existing footprint of the previous 3.75-ton Ansul tank. The new storage tank must be fitted to work and not compromise the integrity of the fire suppression system such as the inlet values, pressure switches and controls, outlet valves, & voltages.

    For the purposes described herein, the USACE Nashville District intends to issue a sole source solicitation that will include the brand name items listed below:

    Manufacturer: Janus Fire Systems

    Quantity: 1

    Items: 4-Ton Janus Low Pressure

    The ANSI, ASME, OSHA, and EM385  standards listed below must be met for technical acceptance.

                    A Voltage Requirement

                                    A1. 460V, 3 phase, 60HZ

                    B Pressure requirements and Valves

                                    B1. Pressure switch (inside)

                                                    B2. Pressure and liquid level gauges

                                    B3. Bleeder valve

                                    B4. ASME VII approved safety valve

                                    B5. Relief valve

                                    B6. Manually actuated wafer valve (carbon steel, 6”)

                                    B7. Ball valve (manual limit switch, ½”)

                                    B8. Pressure regulator

    This Notice of Intent is not a request for competitive quotes. All responsible sources may identify their interest and submit clearly articulated product information. Product information provided will be considered solely at the discretion of the Government. The proposed contract action is for supply for which the Government intends to solicit and negotiate with only one source under the authority of FAR 6.302-1. Interested persons may identify their interest and capability to respond to the requirement or submit proposals. Responses must be received by September 15, 2025 at 1:00PM, Central Daylight Time to be considered. A determination by the Government not to compete with this proposed contract based upon responses to this notice is solely within the discretion of the Government. Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement.

    The Government will not be responsible for any cost incurred in preparation of your response. Submit a response and questions to this notice to, Contract Specialist Kenyanna Jennings: Kenyanna.l.Jennnings@usace.army.mil. The posting of this Notice satisfies the provisions set forth in FAR Subpart 5.2, Synopses of Proposed Contract Action.

    Key dates

    1. September 10, 2025Posted Date
    2. September 15, 2025Proposals / Responses Due

    AI search tags

    Frequently asked questions

    JANUS LOW PRESSURE CARBON DIOXIDE REFRIGERATED STORAGE UNIT FOR CENTER HILL DAM is a federal acquisition solicitation issued by DEPT OF DEFENSE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.