Closed Solicitation · DEPARTMENT OF HEALTH AND HUMAN SERVICES

    Olink Explorer >5400

    Sol. 75N98026Q00800SolicitationSet-aside: No Set aside usedBETHESDA, MD
    Closed
    STATUS
    Closed
    closed Jul 25, 2026
    POSTED
    Jul 15, 2026
    Publication date
    NAICS CODE
    541380
    Primary industry classification
    PSC CODE
    Q301
    Product & service classification

    AI Summary

    The National Institutes of Health is soliciting proposals for a product that measures over 5,400 human proteins using Proximity Extension Assay technology. The product must demonstrate high specificity, a broad dynamic range, and low sample volume requirements, making it suitable for advanced medical research and epidemiology studies.

    Contract details

    Solicitation No.
    75N98026Q00800
    Notice Type
    Solicitation
    Set-Aside
    No Set aside used
    Posted Date
    July 15, 2026
    Response Deadline
    July 25, 2026
    NAICS Code
    541380AI guide
    PSC / Class Code
    Q301
    Contract Code
    7529
    Primary Contact
    John Burton
    State
    MD
    ZIP Code
    20892
    AI Product/Service
    product

    Description

    Requirements: 2.0 BACKGROUND Our lab studies the role of inflammation/innate resistance and commensal microbiota in carcinogenesis, cancer progression and therapy of cancer. The following product features/characteristics are required for this requirement: Protein Coverage - Measures ~5,400+ human proteins simultaneously in a single workflow. Technology - Uses Proximity Extension Assay (PEA) with dual antibody recognition coupled to DNA barcoding and next-generation sequencing (NGS) readout. Sample input – requires only 2 ul of plasma, serum, and other sample types Specificity - Reported 99.5% specificity with negligible cross-reactivity due to dual-recognition antibody design. Dynamic Range - Approximately 10 orders of magnitude (fg/mL to mg/mL), enabling detection of both low- and high-abundance proteins. Key strengths Very broad proteome coverage while maintaining antibody-based specificity. Excellent sensitivity for low-abundance circulating proteins (especially cytokines and signaling proteins). Extremely low sample-volume requirement. Highly standardized platform, making it attractive for epidemiology and multi-omics studies.

    Key dates

    1. July 15, 2026Posted Date
    2. July 25, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    Olink Explorer >5400 is a federal acquisition solicitation issued by DEPARTMENT OF HEALTH AND HUMAN SERVICES. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.