Active Solicitation · DEPARTMENT OF JUSTICE

    REPLACEMENT OF CHILLERS AND PUMPS - FCC OAKDALE, LA

    Sol. 15BGCS26Q51800001Sources SoughtGRAND PRAIRIE, TX
    Open · 98d remaining
    DAYS TO CLOSE
    98
    closes Sep 29, 2026
    POSTED
    Jun 22, 2026
    Publication date
    NAICS CODE
    333415
    Primary industry classification
    PSC CODE
    4130
    Product & service classification

    AI Summary

    The Federal Bureau of Prisons is seeking capable contractors to supply air-cooled chillers and centrifugal pumps for FCC Oakdale. This Sources Sought Notice is for market research and does not constitute a solicitation. Interested vendors should provide capability statements and relevant information by June 29, 2026.

    Contract details

    Solicitation No.
    15BGCS26Q51800001
    Notice Type
    Sources Sought
    Posted Date
    June 22, 2026
    Response Deadline
    September 29, 2026
    NAICS Code
    333415AI guide
    PSC / Class Code
    4130
    Issuing Office
    FAO
    Primary Contact
    Jim Seratt
    State
    TX
    ZIP Code
    75051
    AI Product/Service
    product

    Description

    FCC Oakdale – B&F PROJECT 26Z5AW6
    Replace Chillers and Pumps – Supply Only

    This is a Sources Sought Notice issued for market research information and planning purposes only. It does not constitute a solicitation and responses to this notice are not offers and cannot be accepted by the Government to form a binding contract.

    Participation is voluntary and a response is not required to compete in any potential future solicitation. However, responses to this notice may influence the Government’s development of a future requirement and future acquisition strategy (e.g. set-aside, full and open competition).

    Respondents will not be notified of the results of this market research effort. No reimbursement will be made for any costs associated with responding to this Sources Sought Notice.

    1. Agency and Location

    Federal Bureau of Prisons (FBOP)
    Federal Correctional Complex (FCC) Oakdale
    1507 East Whatley Road, Oakdale, LA 71463

    2. Purpose

    FCC Oakdale seeks to identify capable contractors able to furnish and deliver air‑cooled chillers, centrifugal pumps, and provide manufacturer‑certified start‑up services. Installation will be performed by FCC Oakdale HVAC staff.

    3. Required Equipment and Salient Characteristics

    All equipment must be new, meet all Federal, State, and local codes, and conform to the salient characteristics below. Information is taken directly from the specification sheet.

    A. Chillers

    1. Trane Sintesis Air‑Cooled Chiller – Model RTAF115E (Brand Name or Equal)

    Quantity: Nine (9)
    Salient Characteristics:
    • 115 nominal tons
    • High‑efficiency unit
    • Voltage: 460V / 60Hz / 3‑phase
    • Refrigerant: R‑513A
    • UL listed
    • ASME pressure vessel code compliant
    • Meets ASHRAE 90.1 (all versions up to 2016)

    2. Trane CGAM Air‑Cooled Scroll Chiller (Brand Name or Equal)

    Quantity: Two (2)
    Salient Characteristics:
    • 80 nominal tons
    • High‑efficiency unit
    • Voltage: 460V / 60Hz / 3‑phase
    • Refrigerant: R‑454B
    • UL listed
    • ASME pressure vessel code compliant
    • Meets ASHRAE 90.1 (all versions up to 2016)

    B. Centrifugal Pumps

    (All pumps Bell & Gossett Series 1510 or equal.)

    1. Pump Set A

    Quantity: Ten (10)
    Salient Characteristics:
    • 8" impeller
    • 150 GPM
    • 100 ft head
    • 5 HP
    • 230–460V
    • 2½" discharge
    • 3" suction

    2. Pump Set B

    Quantity: Nine (9)
    Salient Characteristics:
    • 8" impeller
    • 150 GPM
    • 100 ft head
    • 5 HP
    • 230–460V
    • 2" discharge
    • 2½" suction

    C. Chiller Start‑Up Services

    Following in‑house installation, the contractor shall provide a certified manufacturer’s representative to perform initial start‑up of all chillers.

    4. Delivery Requirements

    Contractor shall:
    • Verify quantities prior to shipment
    • Provide factory‑supplied components, controls, and accessories
    • Deliver all equipment to FCC Oakdale
    • Provide manufacturer product data, installation requirements, and warranty materials
    • Coordinate delivery with the Government
    • Deliver equipment new and free of damage
    • Complete delivery within 270 days after contract award

    5. Submittals Required Upon Delivery

    • Product data sheets
    • Manufacturer specifications
    • Chiller shop drawings
    • Equipment schedules
    • Warranty documentation

    6. Applicable NAICS Codes and Size Standards

    333415 – Air‑Conditioning and Warm Air Heating Equipment and Commercial Refrigeration Manufacturing
    • Small Business Size Standard: 1,350 employees

    7. Requested Information from All Interested Vendors To Be Provided on Company Letterhead

    1. Company name, address, point of contact, phone, email
    2. UEI and CAGE code
    3. Capability statement showing ability to supply equipment meeting all salient characteristics
    4. Estimated delivery timeframes
    5. Past performance examples for similar HVAC equipment supply
    6. Any applicable GSA/FSS/GWAC contract numbers
    7. Current number of Employees
    8. Current business size/status for your organization for the NAICS code listed above
      1. List any socio-economic statuses applicable for the organization
         
      2. Are any stated socio-economic status(es) certified and active in the SBA’s Small Business Search (https://search.certifications.sba.gov)? (e.g. VOSB, SDVOSB, WOSB, EDWOSB)
         
    9. Required Information from Small Business Nonmanufacturers of the Equipment Being Procured To Be Provided on Company Letterhead
      1. Confirm that your company is primarily engaged in retail or wholesale and normally sells the type of equipment being procured
      2. Confirm that your company intends to take ownership or possession of the equipment being procured in a manner consistent with industry practice
      3. Identify the manufacturer from which you intend to obtain the equipment being procured
      4. Confirm your organization is aware and capable of meeting the requirements of clause 52.219-33, Nonmanufacturer Rule, should they be successful for a future award.

    8. Response Deadline

    Responses requested by:
    June 29, 2026

    9. Submission Contact

    Jim D. Seratt
    Contracting Specialist (Contractor)

    Field Acquisition Office
    Federal Bureau of Prisons
    Email: jseratt1@bop.gov

    Key dates

    1. June 22, 2026Posted Date
    2. September 29, 2026Proposals / Responses Due

    AI search tags

    Frequently asked questions

    REPLACEMENT OF CHILLERS AND PUMPS - FCC OAKDALE, LA is a federal acquisition solicitation issued by DEPARTMENT OF JUSTICE. Review the full description, attachments, and submission requirements on SamSearch before the response deadline.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.