Active SLED Opportunity · TEXAS · CITY OF WICHITA FALLS

    RFP 03-26 The Falls Renovation CMaR - CWF26-460-12

    Issued by City of Wichita Falls
    cityRFPCity of Wichita FallsSol. 69e146a0caa7222a3acb8197
    Open · 26d remaining
    DAYS TO CLOSE
    26
    due May 19, 2026
    PUBLISHED
    Apr 16, 2026
    Posting date
    JURISDICTION
    City of
    city
    NAICS CODE
    236220
    AI-classified industry

    AI Summary

    RFP for upgrades and improvements to The Falls in Wichita Falls, TX, including demolition, pump replacement, trail widening, retaining wall construction, landscaping, lighting, electrical building replacement, and PLC control system installation.

    Opportunity details

    Solicitation No.
    69e146a0caa7222a3acb8197
    Type / RFx
    RFP
    Status
    Active
    Level
    city
    Published Date
    April 16, 2026
    Due Date
    May 19, 2026
    NAICS Code
    236220AI guide
    State
    Texas
    Agency
    City of Wichita Falls

    Description

    Upgrades and improvements to The Falls (manmade waterfall, landscaping, and trail) including:
    • Demolition of rock veneer and select removal of dry-stack rock;
    • Replacement of metal intake well and screen;
    • Replacement of 3,600 gpm, 100-HP main pump, piping, valves, and controls;
    • Installation of 3,600 gpm, 50-HP recirculation pump, piping, valves and controls;
    • Replacement of two pump manhole lids (main pump and recirculation pump manholes) with a fixed concrete top with pump access hatch and safety screen;
    • Widening of approximately 1,050 linear feet (LF) of concrete trail,
    • New 140-linear foot x 10-foot high retaining wall with rock veneer;
    • Landscaping and irrigation;
    • Replacement of area lighting with LED area and pathway lighting;
    • New programmable LED flood lighting (three pole-mounted Lumascape Kokolux or equal with RGB capability) ;
    • Replacement of electrical building with 100 square-foot (approximate) building;
    • Existing transformer will feed a new 480V, 400A NEMA 3R rated main disconnect. The main disconnect will feed a 480V, 600A bus, NEMA 1 motor control center which will distribute power to all motors and lighting for the site; and
    • A new PLC control panel will be installed with a Schneider Modicon PLC TM251MESE and cellular modem for communication.

     

    ## Details **Bid/Project ID:** 03-26 **Type of Work:** Public Works Construction / Professional Services **Pre-Bid Location:** 1300 7th Street, 1st Floor, Room 1D32, Wichita Falls, Texas 76301 **Pre-Bid Notes:** Engineering Conference Room **Bid Location:** 1300 7th Street, 2nd Floor, Room 2B18, Wichita Falls, Texas 76301 **Bid Notes:** Office of the Purchasing Manager **Engineer/Publisher:** City of Wichita Falls **Engineer Address:** 1300 7th Street, Purchasing Department, Wichita Falls, Texas, 76301

    Key dates

    1. April 16, 2026Published
    2. May 19, 2026Responses Due

    AI classification tags

    Frequently asked questions

    SLED stands for State, Local, and Education. These are solicitations issued by state governments, counties, cities, school districts, utilities, and higher education institutions — as opposed to federal agencies.

    SamSearch Platform

    Stop searching. Start winning.

    AI-powered intelligence for the right opportunities, the right leads, and the right time.